| Plan Review Notes For Permit 08120094 |
| Permit Number |
08120094 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-12-04 16:41:28 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT A1 DEMO/PROPOSED NOTES NUMBER INDICATES REMOVAL | | | OF KITCHEN CABINETS AND FIXTURES IN ITS ENTIRITY, BUT | | | DOES NOT SHOW THEM REINSTALLED. ALSO THE LAUNDRY DOES | | | NOT SHOW A WASH MACHINE CONNECTION AS REQUIRED IN TABLE | | | 403.1. PLEASE CLAIFY. -- SUBMIT AN EXISTING FLOOR PLAN | | | SO THAT THE EXTENT OF THE WORK CAN BE VERIFIED. SECTION | | | 106.1.2. | | | | | | 2. SUBMIT A SANITARY RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, P-TRAPS, AND VENTS. SHOW CONNECTIONS TO THE | | | STACKS AND INDICATE EXISTING FIXTURES BELOW OR ON THE | | | SAME FLOOR CONNECTING TO THE EXISTING STACKS. SECTION | | | 106.3.5.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|