| 2008-12-09 11:53:46 | RESIDENTIAL (R3) REMODEL/ALTERATION BUILDING REVIEW |
| | CHECKLIST. |
| | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 |
| | REVISIONS. |
| | |
| | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED |
| | BY SEC. 713.13 FLORIDA STATUTE. |
| | NOTE: THIS MAY BE PROVIDED AT TIME OF PERMIT PICK UP. |
| | |
| | 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) NEW SINGLE HUNG WINDOWS. |
| | |
| | B) WINDOW MULLIONS. |
| | |
| | C) FRENCH DOORS AS SHOWN ON PLANS. |
| | |
| | D) SHUTTERS IF WINDOWS/DOORS DON'T HAVE IMPACT GLAZING. |
| | NOTE: ALSO, PROVIDE SHUTTERS COMPLETE INSTALLATION |
| | SCHEDULE AND CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS AND ANCHOR TYPE AND SPACING TO BE |
| | USED AS REQUIRED BY CITY IMPLEMENTATION STANDARD FOR |
| | WIND-BORNE DEBRIS IMPACT PROTECTION. SEE ATTACHED |
| | SAMPLE. |
| | |
| | E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| | AND DETAILS. |
| | NOTE: PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND PAGE WHERE CONNECTOR IS SHOWN. NO NEED TO |
| | SUBMIT COMPLETE REPORT. THIS APPLIES TO STRUCTURAL |
| | CONNECTORS ONLY. |
| | |
| | 3- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT |
| | SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED |
| | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 4- SPECIFY SAFETY GLASS FOR NEW WINDOWS IN MASTER BATH |
| | AS REQUIRED BY SEC. R308.4 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | |
| | 5- ALL NEW EXTERIOR STAIRS NEED TO COMPLY WITH THE |
| | RISER TREAD RATIO OF SEC. R311.5.3.2 OF 2004 FLORIDA |
| | RESIDENTIAL CODE. REVISE PLANS AS REQUIRED. |
| | |
| | 6- PROVIDE DIMENSIONS FOR NEW INTERIOR STAIRWAY TO |
| | VERIFY COMPLIANCE WITH SECTIONS R311.5.1 FOR STAIR |
| | WIDTH AND R311.5.4 FOR STAIR LANDING OF 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 7- PROVIDE DIMENSIONS FOR ROOM ADJACENT TO NEW STAIRS |
| | TO VERIFY COMPLIANCE WITH THE MINIMUM ROOM SIZES |
| | REQUIREMENTS OF SEC. R304 OF 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | NOTE: WRITTEN DIMENSIONS (7'-6") SHOWN ON THE FLOOR |
| | PLANS DON'T MATCH SCALED DIMENSIONS. ARE THE FLOOR |
| | PLANS DRAWN TO SPECIFIED SCALE. ALSO, COORDINATE THIS |
| | ITEM WITH DIMENSIONS GIVEN ON ITEM #5 ABOVE. DRAW PLANS |
| | TO EXACT SCALE AND PROVIDE CORRESPONDING WRITTEN |
| | DIMENSIONS. |
| | |
| | 8- SHEET A3: REVISE STRUCTURAL DESIGN CRITERIA AND |
| | CODES NOTE. WIND LOADS TO BE BASED ON ASCE 7-02 NOT |
| | ASCE 7-98. REVISE AS REQUIRED. |
| | |
| | 9- SHEET A-5: REVISE TYPICAL RAILING DETAIL TO COMPLY |
| | WITH SEC. R311.5.6.3 OF 2004 FLORIDA RESIDENTIAL CODE. |
| | NOTE: SEE ATTACHED TYPE II HANDRAIL DETAIL TAKEN FROM |
| | THE 2004 FLORIDA RESIDENTIAL CODE COMMENTARY FOR |
| | REQUIRED DIMENSIONS AND REVISE DETAIL AS REQUIRED. |
| | |