| 2009-03-09 15:19:31 | BUILDING PLAN REVIEW |
| | PERMIT: 08110518 |
| | ADD: 2400 N FLAGLER |
| | CONT: PLAN REVIEW |
| | TEL: (561)248-5574/ CARL SHEPARD |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2ND REVIEW |
| | MARCH 09/09 |
| | ACTION: DENIED |
| | |
| | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS. |
| | |
| | 2) COMPLIED. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) COMPLIED. |
| | |
| | 5) BOAT ADA LIFT REMOVED FROM SHEET 1 THROUGH 7. ADA |
| | TRANSFER OR BOAT LIFT, PLEASE PROVIDE INFORMATION |
| | .TITLE III OF THE ADA PUBLIC TRANSPORTATION SYSTEMS AND |
| | TITLE II PUBLIC FACILITY. |
| | |
| | 6) SEMI-COMPLIED. PLANS NOW SHOW A GUARD RAIL ON THE |
| | SIDES OF THE FLOATING DOCK WHERE BOATS ARE NOT LOADING. |
| | THE PROBLEM IS THE 1012.3 OPENING LIMITATIONS, THE |
| | GUARD IS TO BE ABLE TO REJECT A 4" SPHERE, THE PLANS |
| | FOR BOTH THE FLOATING DOCK AND GANGWAY DO NOT INDICATE |
| | THIS. |
| | |
| | 7) 2ND REQUEST, SHEET 6 INDICATES THE USE OF HURRICANE |
| | STRAPS OR TIES, RULE 9-B REQUIRES PRODUCT APPROVALS FOR |
| | SUCH ITEMS, RULE 9-B(31)(G). |
| | 106.3 PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO |
| | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| | SITE SPECIFIC FORM PER RULE 9B-72. |
| | |
| | 8) NOT TO BE ENFORCED BY RULE OF NEW B.O. |
| | |
| | 9) ELECTRICAL SHEET# 4 INDICATES THE USE OF LIGHT POLES |
| | BUT AGAIN THERE IS NO DESIGN CRITERIA FOR WIND, |
| | 1603.1.4. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | |