2009-02-04 18:03:472004 FBC W/2007 REVISIONS
 ADDITION AND REMODEL
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) SHOW COMPLIANCE WITH R320.1 TERMITE PROTECTION SHALL
 BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL
 APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES
 APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE
 PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT
 TO NEW CONSTRUCTION (SEE SECTION 202, REGISTERED
 TERMITICIDE). PLEASE SPECIFY THE METHOD THAT WILL BE
 USED ON THE PLANS.
  
 3) SPECIFY THE UPLIFT CAPACITY FOR THE SIMPSON MGT
 CONNECTOR IN THE SCHEDULE ON SHEET 7. R 801.2. PLEASE
 INDICATE THIS ON THE PLANS.
  
 4) SUBMIT PRODUCT APPROVALS FOR THE TRUSS CONNECTORS OR
 SPECIFY THE FL#S FOR THEM IN THE CONNECTOR SCHEDULE.
 FAC RULE 9B-72
  
 5) SUBMIT PRODUCT APPROVALS FOR THE SLIDING HORIZONTAL
 SLIDING KITCHEN WINDOW. THE ONES THAT WERE SUBMITTED
 ARE FOR A SLIDING GLASS DOOR WITH MINIMUM HEIGHT OF
 6'-8". RULE 9B-72 THIS IS ACCEPTABLE AS LONG AS THE
 ALTERATIONS TO CUT DOWN THE SIZE OF THE DOOR IS
 PERFORMED BY THE MANUFACTURER.
  
 6) SUBMIT PRODUCT APPROVALS FOR THE GLASS BLOCK. FAC
 RULE 9B-72
  
 7) SPECIFY THE WIDTH OF THE REAR FRENCH DOOR AND
 SIDELITES ON THE PLANS. R301.2.1 AN APPROXIMATE WIDTH
 IS REQUIRED TO DETERMINE IF THE PRODUCT APPROVAL IS
 ADEQUATE.
  
 8) IF CASEMENT WINDOWS ARE TO BE USED, PLEASE SUBMIT
 PRODUCT APPROVALS FOR THEM. DCA RULE 9B-72.
  
 9) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE
 FRENCH DOOR IS FOR AN OUT-SWING DOOR, PLEASE SUBMIT
 PRODUCT APPROVALS FOR THE FRONT IN-SWING DOOR. DCA RULE
 9B-72
  
 NOTE: FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS.
 THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. HAVE ALL NEW PRODUCT APPROVALS
 REVIEWED BY THE D.O.R.
  
 PLEASE SUBMIT THE OLD PLAN SHEETS WHICH HAVE THE PALM
 BEACH COUNTY IMPACT FEE STAMP ON THEM AS WELL AS A COPY
 OF THE PAID RECEIPT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved