Plan Review Notes
Plan Review Notes For Permit 08110356
Permit Number 08110356
Review Stop P
Sequence Number 1
Notes
Date Text
2008-12-02 10:08:40DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
  
 1. SUBMIT A SANITARY AND WATER RISER DIAGRAM TO REFLECT
 ALL WORK SHOWN ON THE FLOOR PLAN. FOR THE SANITARY SHOW
 ALL PIPE SIZES, TRAPS, VENTS, CONNECTIONS TO WASTE
 STACKS & VENT THRU THE ROOF. FOR WATER SHOW ALL PIPE
 SIZES, VALVES AND, (WHERE REQUIRED BY SECTION 604.9),
 WATER HAMMER ARRESTORS. SECTIONS
 106.3.5.1.3(3)(4)(5)(6)(10)(13) 601.1, 604.1, 604.5,
 701.1, 704.1, 708, 709, 710, 901.1, 904, 905 & 916.
  
 2. THE ENERGY EFFICIENCY CALCULATIONS INDICATE "N/A"
 FOR THE HOT WATER, BUT THE PLANS INDICATE A TANKLESS
 WATER HEATER FOR THE P-4 SINK IN THE BREAK ROOM. PLEASE
 CLARIFY/CORRELATE. SECTION 13.
  
 3. SHT A-1.01 HAS WHITE OUT FOR THE APPLICABLE CODES ON
 THE DATE FOR THE 2007 SUPPLEMENTS. PER SECTION 106.1.3
 WHITE OUT IS NOT APPROVED ON PLANS SUBMITTED FOR PUBLIC
 RECORD.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  