2008-11-25 11:56:37PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK
 EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS
 "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 4. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF
 THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL
 PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY
 LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE
 APPLICATION.
  
 5. PLEASE CORRELATE ALL PLANS. THE SETBACK DIMENSIONS
 SHOWN ON THE SITE PLAN (SHEET 2 OF 8) DIFFER FROM BOTH
 THE FOUNDATION AND FLOOR PLAN.
  
 6. IF APPLICABLE, INDICATE SETBACK DIMENSIONS FROM
 PROPOSED OR RELOCATED A/C EQUIPMENT TO ALL PROPERTY
 LINES. PURSUANT THE ZLDR, SECTION 94-305(B)(4):
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
 7. VERIFY THAT THE PROPOSED ADDITION DOES NOT INTEFERE
 WITH THE REQUIRED 75% OF REQUIRED LANDSCAPING IN THE
 FRONT YARD. PURSUANT TO THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-482: REQUIRED OFF-STREET PARKING SPACES FOR LESS
 THAN FOUR RESIDENTIAL DWELLING UNITS SHALL BE LOCATED
 ON THE PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED.
 REQUIRED PARKING MAY BE LOCATED IN A FRONT YARD;
 HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT
 OF THE FRONT YARD AREA MUST BE LANDSCAPED. PARKING
 AREAS LOCATED IN THE FRONT YARD SHALL BE SURFACED WITH
 A SMOOTH, NONDUSTING SURFACE IN COMPLIANCE WITH
 SUBSECTION 33-485(E). IT SHALL BE A VIOLATION OF THIS
 CHAPTER TO PARK ON ANY UNPAVED AREAS AS DESCRIBED IN
 THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  