| Date |
Text |
| 2008-12-04 09:54:16 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. PLEASE SEE ZONING COMMENTS. CODE COMPLIANCE WITH FBC |
| | TABLE 602 MUST BE SHOWN AS, WHEN PERMITTED, CODE |
| | COMPLIANCE WAS DEMONSTRATED BASED ON AN ASSUMED |
| | PROPERTY LINE BETWEEN TWO BUILDINGS RATHER THAN |
| | DISTANCE TO THE PROPERTY LINE. IT APPEARS THAT THERE IS |
| | NO ISSUE IN THIS CASE, BUT PLEASE SHOW CMOPLIANCE WITH |
| | FBC TABLE 602, 704.8. |
| | |
| | 2. FBC EB 301.5, DECLARE LEVEL OF ALTERATION. |
| | |
| | 3. INFORMATIONAL ONLY - THE ADDRESS DOES NOT MATCH PAPA |
| | RECORDS. THE CITY IS WORKING WITH THE COUNTY TO GET |
| | PAPA RECORDS CHANGED TO REFLECT THE CORRECT ADDRESS. |
| | |
| | 4. SHEET SP1, A03, DOCUMENTS PREPARED BY AN ARCHITECT |
| | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, |
| | SEALED, DATED ORIGINALS FS481. IT IS LIKELY THAT THIS |
| | WAS SUBMITTED FOR INFORMATIONAL PURPOSES ONLY, BUT DUE |
| | TO COMMENT #1 THIS IS REQUIRED TO SHOW CODE COMPLIANCE. |
| | PLEASE ALSO BE ADVISED THAT, EVEN IF SUBMITTED AS |
| | INFORMATIONAL ONLY, THE FLORIDA STATUTE STILL APPLIES |
| | (NO EXEMPTION TO BEING SIGNED AND SEALED). |
| | |
| | 5. THE SITE PLAN SUBMITTED SHOWS A RAMP IN THE ACCESS |
| | AISLE. FBC11-4.6.3 REGARDING ACCESS AISLE SLOPE, 2% IN |
| | ALL DIRECTIONS. THIS IS IN CONFLICT WITH THE STATEMENT |
| | ON THE PLAN THAT STATES THAT VARIOUS ELEMENTS ARE IN |
| | COMPLIANCE WITH ADAAG. |
| | |
| | 6. ALL INFORMATION REQUIRED BY FAC61G1-15.003, 004, IS |
| | REQUIRED ON EACH SHEET (CERTIFICATE OF AUTHORIZATION |
| | FOR T. Y. LIN INTERNATIONAL). |
| | |
| | 7. THE ADDRESS IN THE TITLE BLOCK FOR T. Y. LIN |
| | INTERNATIONAL DOES NOT MATCH THE WEBSITE, |
| | MYFLORIDALICENSE.COM. |
| | |
| | 8. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVALS FOR |
| | THE 4'X5' DRIVE THRU WINDOW, FAC9B72 (+33.7/-36.7PSF DP |
| | REQUIRED SHEET A0.0). |
| | |
| | |
| | |