Notes
Date Text
2008-12-04 11:52:551. PLEASE CLARIFY IF THE SUBMITTED BUILDING PERMIT
 INCLUDES THE HOTEL AND THE PARK OR IT IS ONLY FOR THE
 HOTEL. PLEASE INLCUDE DATA TO CONFIRM THE AREA OF THE
 PROPOSED PARK IS MINIMUM OF 12,500 SQUARE FEET.
 2. THE TOTAL GROSS SQUARE FOOTAGE ON PAGE A002 DOES NOT
 MATCH THE TOTAL SQUARE FOOTAGE ON PAGE A00A
 3. LANDSCAPE DRAWINGS DO NOT MATCH ROOF PLAN ON SHEET
 A104 AND A104C.
 4. LANDSCAPE DRAWINGS FOR PARK SHOULD REFLECT THE
 LATEST FOOTPRINT CHANGES FOR THE ANNEX. LANDSCAPE
 DRAWINGS SHOULD NOT INCLUDE ANYTHING RELATED TO THE
 CENTRAL PARK PLAZA BUILDING (NORTH OF FERN)
 5. INFORMATION SHOULD BE PROVIDED REGARDING THE
 PROPOSED LOCATION FOR THE PARKING SPACES REQUIRED FOR
 THE NEW HOTEL ROOMS ON THE ANNEX BUILDING. 35 SPACES
 ARE REQUIRED BY CODE.
 6. IF PARK IS INCLUDED AS PART OF THIS PERMIT DRAWINGS
 SHALL INCLUDE DETAILS FOR PROPOSED PAVERS, BENCHES,
 DRINKING FOUNTAIN, FOUNTAIN DETAILS, LIGHTING, TREE
 GRATES, AND ANY OTHER ELEMENTS NECESSARY TO ACCURATELY
 DEPICT THE PROPOSED DESIGN FOR CONSTRUCTION.
 7. A TREE RELOCATION PERMIT IS REQUIRED FOR THE REMOVAL
 OF THE TREES CURRENTLY LOCATED AT THE PARKING LOT.
 8. PAVERS PROPOSED FOR PARK AREA MAY EXTEND OVER THE
 PUBLIC SIDEWALK TO CONTINUE THE MAIN PATTERN. SIDEWALK
 IN FRONT OF HOTEL AND ANNEX BUILDING SHOULD MATCH THE
 DIXIE HWAY STREETSCAPE OR FERN STREET SIDEWALK
 MATERIAL.