2008-12-02 12:05:47RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
 NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP TO
 AVOID EXPIRATION.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5120) TO CHECK IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE
 DUE.
  
 3- OWES $3.32 FOR RADON FEES.
  
 4- PROVIDE COMPLETE SPECIFICATIONS FOR NEW UL LISTED
 FIREPLACE.
  
 5- PROVIDE ATTIC ACCESS FOR NEW ROOF AS REQUIRED BY
 SEC. R807 2004 FLORIDA RESIDENTIAL CODE.
 NOTE: PLEASE MAKE SURE LOCATION AND HEADROOM COMPLIES
 WITH THIS SECTION.
  
 6- NEW WINDOWS DON'T COMPLY WITH THE EGRESS
 REQUIREMENTS OF SEC R310 OF 2004 FLORIDA RESIDENTIAL
 CODE. CLARIFY IF EXISTING WINDOWS COMPLY WITH SEC.
 R310. SPECIFY TYPE OF EXISTING WINDOWS AND SIZE TO
 VERIFY MINIMUM WIDTH, HEIGHT AND MINIMUM TOTAL OPENING
 (5.7S.F.).
  
 7- SPECIFY HOW ARE CONCRETE ROOF TILES FASTENED AS
 REQUIRED BY SEC. 106.1.1.2 CITY AMENDMENTS TO FBC 2004.
 PROVIDE PRODUCT APPROVAL IF USING ADHESIVE. SEE TILE
 PRODUCT APPROVAL FOR SPECIFIC ADHESIVE TO BE USED. IF
 USING NAILS OR SCREWS, SPECIFY SIZE AND NUMBER TO
 VERIFY COMPLIANCE WITH THE UPLIFT LOADS. SEE PRODUCT
 APPROVAL.
  
 8- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY CHAPTER
 11 OF 2004 FLORIDA RESIDENTIAL CODE.
 NOTE: MAKE SURE CORRECT 2004 REVISED FORM IS USED TO
 AVOID DELAYS. ALSO, COORDINATE WITH PLANS FOR CORRECT
 INSULATION TYPE AND VALUES TO BE USED.
  
 9- PROVIDE COMPLETE SPECIFICATIONS FOR ICYNENE
 INSULATION TO VERIFY COMPLIANCE WITH PROPOSED
 INSTALLATION.
  
 10- SPECIFY ALL DESIGN LOADS AS REQUIRED BY SEC. R301.1
 INCLUDING THE ATTIC LIVE LOADS OF TABLE R301.5 OF 2004
 FLORIDA RESIDENTTIAL CODE.
  
 11- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED
 BY DCA RULE 9B-72 FOR:
 A) CONCRETE ROOF TILE. NOA 01-0417.09 SUBMITTED EXPIRED
 ON 06/07/06. NEED TO PROVIDE CURRENT NOA.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS.
 NOTE: PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND PAGE WHERE CONNECTOR IS SHOWN.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712