| Plan Review Notes For Permit 08110101 |
| Permit Number |
08110101 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-11-08 09:31:26 | | | | | | | DENIED | | | | | | 1) THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY. THE ENGINEERING WIND LOAD SHEET | | | IS FOR EXP. B | | | | | | 2) ENGINEERED SHOP DRAWINGS SPECIFY 1/4 " TEMPERED | | | GLASS, THIS IS NOT A TESTED AND APPROVED GLAZING TYPE | | | IN THE PRODUCT APPROVAL DOCUMENTS BUT YOU DO HAVE THE | | | TYPE 2 GLAZING (5/16" HEAT STRENGTHENED) SPECIFIED IN | | | THE CONTRACT. PLEASE CLARIFY. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | |
|