| Plan Review Notes For Permit 08110081 |
| Permit Number |
08110081 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-12-09 16:57:59 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | | | | 1. SHT 1 DEMO SHEET, DEMOLITION NOTES STATE CAP ALL | | | REMOVED PLUMBING FLUSH WITH THE FLOOR AND BEHIND | | | GYPBORD AT CHASE PARTITIONS. PER SECTION 704.5 IN THE | | | REMOVAL OF ANY DRAINAGE PIPING, DEAD ENDS ARE | | | PROHIBITED. ALL SANITARY DRAINAGE PIPING SHALL BE | | | CAPPED OFF WITHIN TWO FEET OF AN ACTIVE BUILDING DRAIN. | | | PLEASE INDICATE ON THE PLANS WHERE THE PIPING WILL BE | | | CAPPED OFF. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|