2008-12-02 12:02:122004 FBC W/2007 REVISIONS
 NSFD
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SOME OF THE CODE REFERENCES ON THE PLANS DO NOT
 SPECIFY THE 2007 REVISIONS TO THE 2004 FBC. PLEASE
 CORRECT.
  
 4) SHOW COMPLIANCE WITH R502.1.2 DRAFTSTOPPING
 REQUIRED.
 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE
 CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS
 SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED
 SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING
 SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY
 EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR
 MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW
 DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING
 ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES:
 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.
 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB
 OR PERFORATED MEMBERS.
  
 5) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING
 FASTENINGS.
 WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO
 ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 INCHES ON
 CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE
 FRAMING. RING-SHANK NAILS SHALL HAVE THE FOLLOWING
 MINIMUM DIMENSIONS:
 1. 0.113-INCH NOMINAL SHANK DIAMETER
 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER
 3. 16 TO 20 RINGS PER INCH
 4. 0.280 INCH FULL ROUND HEAD DIAMETER
 5. 2-INCH NAIL LENGTH
 WHERE ROOF FRAMING WITH A SPECIFIC GRAVITY, 0.42 < G <
 0.49 IS USED, SPACING OF RING-SHANK FASTENERS SHALL BE
 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130 MPH OR
 GREATER DESIGN WIND SPEEDS IN ACCORDANCE WITH FIGURE
 R803.2.3.1.
  
 6) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE
 ENERGY CALCULATION FORMS. FBC 13-600.
  
 7) SUBMIT SOIL TEST REPORTS THAT HAVE THE ORIGINAL WET
 SIGNATURE OF THE ENGINEER THAT SEALS THE DOCUMENTS AS
 REQUIRED BY FS 471 AND FAC 61G15-23.002. COPIED
 SIGNATURES OR SIGNATURE STAMPS ARE NOT ACCEPTABLE.
  
 8) SUBMIT TRUSS DRAWINGS AND LAYOUTS THAT HAVE THE
 ORIGINAL WET SIGNATURE OF THE ENGINEER THAT SEALS THE
 DOCUMENTS AS REQUIRED BY FS 471 AND FAC 61G15-23.002.
 COPIED SIGNATURES OR SIGNATURE STAMPS ARE NOT
 ACCEPTABLE. THE TRUSS DOCUMENTS ARE REQUIRED TO BE
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE.
  
 9) THE BOTTOM CORD LIVE LOAD FOR THE ROOF TRUSSES IS
 SPECIFIED AS "0" ON THE TRUSS DRAWINGS. THE MINIMUM
 LIVE LOAD IS 10 PSF FOR ATTICS WITH NO STORAGE. PLEASE
 CORRECT. SEE FBC R301.5
  
 10) THE MEAN ROOF HEIGHT FOR THE STRUCTURE IS SPECIFIED
 AS 25' ON THE TRUSS DRAWINGS AND 27' ON THE TRUSS
 LAYOUT. PLEASE COORDINATE. R202, R301.2.1 AND
 R502.1.3.4
  
 11) SPECIFY THE MEAN ROOF HEIGHT ON THE ARCHITECTURAL
 PLANS. R202 AND R301.2.1
  
 12) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 13) SUBMIT PRODUCT APPROVALS FOR THE TRUSS ANCHORS AND
 CONNECTORS OR SPECIFY THE FLORIDA PRODUCT APPROVAL FL#
 FOR EACH ON THE PLANS. SEE RULE 9B-72.
  
 14) SUBMIT THE CURRENT PRODUCT APPROVAL NOA ( NOA #
 07-1116.09) FOR THE WATKINS SAWMILLS LTD WOOD SHAKES.
 DCA RULE 9B-72
  
 15) THE PRODUCT EVALUATION REPORT FL 7630.1 FOR THE RW
 BUILDING CONSULTANTS FOR THE GLAZED FIBERGLASS DOOR HAS
 THE DRAWINGS FOR A GLAZED STEEL DOOR ATTACHED. PLEASE
 CORRECT. DCA RULE 9B-72
  
 16) THE PRODUCT APPROVAL INFORMATION THAT WAS SUBMITTED
 FOR THE PGT SINGLE HUNG WINDOWS IS INCOMPLETE. SUBMIT
 THE COMPLETE PRODUCT APPROVAL. DCA RULE 9B-72
  
 17) THE INSTALLATION DRAWINGS THAT ARE ATTACHED TO THE
 KOLBE DOOR PRODUCT APPROVAL (FL 8603) ARE FOR
 NON-IMPACT RATED DOORS, ALTHOUGH THE ONE MARKED ON THE
 COVERSHEET IS IMPACT RATED. PLEASE CORRECT. DCA RULE
 9B-72
  
 18) THE PRODUCT APPROVAL FOR THE KOLBE DOOR WITH FL
 4816 IS NO LONGER LISTED ON THE STATE WEBSITE.
 WWW.FLORIDABUILDING.ORG SUBMIT MIAMI-DADE PRODUCT
 APPROVAL. DCA RULE 9B-72
  
 19) IN ORDER TO DETERMINE IF THE DOORS, WINDOWS AND
 MULLIONS HAVE ADEQUATE DESIGN PRESSURES FOR THE
 OPENING, PLEASE SPECIFY ON THE PRODUCT APPROVAL WHICH
 DOORS AND WINDOWS THE PRODUCT APPROVALS CORRESPOND TO.
 DCA RULE 9B-72 AND R301.2.1
  
 20) THE DESIGN PRESSURES LISTED IN THE PRODUCT APPROVAL
 FOR THE 16' WIDE GARAGE DOOR ARE TOO LOW. ALSO PARTS OF
 THE INSTALLATION DRAWINGS ILLEGIBLE. PLEASE SUBMIT
 LEGIBLE COPIES. DCA RULE 9B-72 AND R301.2.1
  
 21) THE INSTALLATION DRAWINGS FOR THE 9' WIDE GARAGE
 DOOR ARE ILLEGIBLE. PLEASE SUBMIT LEGIBLE COPIES. DCA
 RULE 9B-72 AND R301.2.1
  