| Date |
Text |
| 2008-10-31 13:43:30 | BUILDING PLAN REVIEW |
| | PERMIT: 08100508 |
| | ADD: 477 S. ROSEMARY AVE #230 |
| | CONT: SOUTH PALM CONSTRUCTION INC. |
| | TEL: (561)659-5828 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 10-31-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 3) THE TOTAL SQUARE FOOTAGE OF THE NEW SPACE IS |
| | REQUIRED WHEN CALCULATING THE OCCUPANT LOAD. IT SEEMS |
| | AS IF A NEW OPENING IS BEING CREATED TO JOIN TWO SPACES |
| | (SHEET A-1) WHICH MEAN THE GROSS SQUARE FOOTAGE WILL BE |
| | MORE THAN WHAT IS STATED ON THE DRAWINGS. IF THIS IS |
| | TRUE PLEASE INDICATE THE TRUE SQUARE FOOTAGE OF THE NEW |
| | OCCUPIED SPACE. NOTE: THE OCCUPANT LOAD MAY CHANGE |
| | DEPENDING ON THE SQUARE FOOTAGE. |
| | |
| | 4) NOTE: FBC 1008.1.2 DOORS SHALL SWING IN THE |
| | DIRECTION OF EGRESS TRAVEL WHERE SERVING AND OCCUPANT |
| | LOAD OF 50 OR MORE PERSONS. |
| | |
| | 5) SHEET A-3 DETAIL #7 SHOWS THE RECEPTION DESK HEIGHT |
| | AS 3?-6?: SHEET A-4 DETAIL #24 SHOWS THE SAME |
| | DIMENSION. FBC 11-7(2) COUNTERS THAT MAY NOT HAVE A |
| | CASH REGISTER BUT WHERE GOODS OR SERVICES ARE SOLD OR |
| | DISTRIBUTED, SHALL HAVE A PORTION OF THE COUNTER A |
| | MINIMUM OF 36 INCHES IN LENGTH AND A MAXIMUM HEIGHT OF |
| | 36 INCHES OR INDICATE ONE OF THE OTHER OPTIONS |
| | INDICATED. CLARIFY. |
| | |
| | 6) NOW THE SPACE IS BEING ALTERED, SHOW THE NEW LAYOUT |
| | OF THE FIRE SPRINKLER HEADS IN CONFIGURATIONS WITH THE |
| | NEW WALLS AND OFFICES, THIS INFORMATION CAN BE SHOWN ON |
| | THE REFLECTED CEILING PLANS. FBC 106.3.5.1.1(5) |
| | FS553.79 (2) |
| | |
| | 7) SHEET A-1 DETAIL #2: IT APPEARS THE EXISTING LAYOUT |
| | AND OCCUPANCY IS AN R-2, IF THIS IS BEING CHANGED TO A |
| | BUSINESS, THEN THIS IS A CHANGED OF OCCUPANCY WHICH |
| | SHALL BE INDICATED ON THE PLANS AND APPLICATION. WITH |
| | THE CHANGED OF OCCUPANCY THE PLANS SHALL BE TAKEN TO |
| | PALM BEACH COUNTY IMPACT FEE OFFICE FOR EVALUATION OF |
| | PENDING FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 8) WITH THE CHANGE OF OCCUPANCY, PLEASE SHOW THE |
| | ACCESSIBLE BATHROOM FACILITY FOR THE SPACE. WALL WITHIN |
| | 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A |
| | SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 |
| | FEET ABOVE THE FLOOR. FBC 1210.2. PLEASE ALSO SEE FBC |
| | 11-4.16.2/ 11-4.16.3/ 11-4.16.4 ETC AND 11-4.19. |
| | |
| | 9). SINKS: 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE |
| | MOUNTED WITH THE COUNTER NO HIGHER THAN 34" ABOVE THE |
| | FINISH FLOOR. |
| | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" |
| | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. |
| | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT |
| | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) |
| | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR |
| | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL |
| | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE |
| | SINK |
| | |
| | 10) 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE & |
| | EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |