Plan Review Notes
Plan Review Notes For Permit 08100484
Permit Number 08100484
Review Stop P
Sequence Number 2
Notes
Date Text
2009-01-08 11:29:28 
  
  
 PASSED/PROVISO -- REVISION REQUIRED
  
 SHT P.1 SANITARY RISER DIAGRAM. THE COMBINATION DRAIN
 AND VENT SYSTEM, (FOR THE PEDICURE DRAINS), SHALL BE
 PROVIDED WITH A DRY VENT CONNECTED AT ANY POINT WITHIN
 THE SYSTEM. A DRY VENT CAN BE INSTALLED IN THE WALL TO
 THE EAST SIDE OF THE DRAINS TO COMPLY. (SEE RED LINE
 MARK UP ON PLANS). SECTION 912.2.2.
  
 SHT P.1 POTABLE WATER ISOMETRIC RISER DIAGRAM. WATER
 HAMMER ARRESTORS ARE REQUIRED AT THE WASH MACHINE WATER
 SUPPLIES. SECTION 604.9. ARRESTORS SHALL BE INSTALLED
 NEAR THE FIXTURES IN AN "EFFECTIVE RANGE" PER PDI-WH
 201.
  
  
  
  
 .