| Plan Review Notes For Permit 08100397 |
| Permit Number |
08100397 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-10-29 17:08:24 | | | | | | | | | | APPLICATION #08100397 ELECTRICAL PLAN REVIEW | | | 717 S OLIVE AVENUE 10/29/08 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE ADDRESS ON THE APPLICATION IS CORRECT BUT DOES | | | NOT CORRELATE WITH THE ADDRESS ON THE PLANS. | | | | | | 2} SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1 | | | NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID | | | CONFUSION IN THE FIELD. IF USING DETECTORS INDICATE THE | | | LOCATIONS OF THE SOUNDING DEVICES. | | | | | | 3} IT APPEARS THAT THE TUB IN THE MASTER BATH HAS BEEN | | | REPLACED OR REFITTED WITH A RECIRCULATION PUMP. | | | INDICATE COMPLIANCE WITH ARTICLE 680 VII. | | | | | | 4} THE RECEPTACLE IN THE MASTER BATH LOCATED IN THE | | | KNEE SPACE IS INDICATED AS NEW PER THE LEGEND, AND DOES | | | NOT MEET THE SPACING REQUIREMENT OF 215.52(D). | | | | | | 4} INDICATE THE TYPE OF LUMINAIRES AND THE WATTAGES OF | | | SAME, BEING INSTALLED UNDER THIS PERMIT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | |
|