Plan Review Notes
Plan Review Notes For Permit 08100220
Permit Number 08100220
Review Stop P
Sequence Number 2
Notes
Date Text
2009-02-03 11:18:38DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT E-2 SANITARY RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS.
 A. THE LAV IN THE POWDER ROOM IS ON THE RIGHT HAND
 WALL. (SHOWN ON THE LEFT HAND WALL), AND IS NOT VENTED.
 SECTIONS 106.1.1 & 901.2.1.
 B. THE DOUBLE LAVS FOR BATH AT BEDROOMS 3 & 4 ARE SHOWN
 PARALLEL TO THE WALL, NOT OUT INTO THE BATHROOM, AND
 THE SHOWER IS NOT VENTED. SECTIONS 106.1.1 & 901.2.1.
 C. THE SECOND FLOOR GUEST BATHROOM TUB IS NOT VENTED.
 SECTION 901.2.1.
  
 2. SEE RED LINE EXAMPLES SHOWN ON NEW SHEET E-2.
  
 3. REMOVE ALL VOIDED, SUPERSEDED SHEETS AND REPLACE
 WITH NEW SHEETS. PLANS SHALL BE SUBMITTED IN TWO BOUND
 SETS. LOOSE SHEETS NOT APPROVED. SECTION 106.1.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  