Plan Review Notes
Plan Review Notes For Permit 08100061
Permit Number 08100061
Review Stop B
Sequence Number 2
Notes
Date Text
2008-10-17 16:40:58****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. OPENING 6, C4 CONNECTION, 77PSF (YOU HAVE SPECIFIED
 -75 PSF FOR DESIGN PRESSURE ON INSTALLATION SCHEDULE)
 REQUIRES 7" SPACING, NOT 18". PLEASE CHECK ALL
 OPENINGS. NOTE THAT YOU HAVE USED THE ROW FOR 47.2, BUT
 THIS DOES NOT MEET THE DESIGN PRESSURE REQUIREMENTS
 STATED ON THE INSTALLATION SCHEDULE.
  