| Date |
Text |
| 2008-09-26 11:07:26 | GAS PLAN REVIEW: |
| | DENIED: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. |
| | |
| | 1. SUBMIT AN ISOMETRIC DRAWING THAT |
| | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| | AND CORRESPONDING LENGTHS PER FBC-2004 |
| | FUEL GAS CODE SECTION 401.1 SCOPE. |
| | *NOTE: THE SUBMITTED ISOMETRIC DOES NOT INDICATE |
| | CORRESPONDING LENGTHS TO ALL CUT SECTION OF PIPE. |
| | PLEASE REFERENCE THE YELLOW HIGH LIGHTED CUT SECTIONS |
| | WITH NO CORRESPONDING LENGTHS AND COMPLY ON THE |
| | RESUBMITTAL. |
| | |
| | 2. SHOW TYPE OF PIPING MATERIAL BEING |
| | INSTALLED, ALL PIPE SIZES, (AND THE EDH |
| | NUMBER OF CORRUGATED STAINLESS STEEL |
| | TUBING FOR EACH PIPE SIZE BEING USED. |
| | PER FBC-2004 FUEL GAS SECTION 401.1 SCOPE. |
| | *NOTE: THE SUBMITTED ISOMETRIC DOES NOT CLEARLY |
| | INDICATE THE ABOVE GROUND PIPING MATERIAL TO ALL CUT |
| | SECTIONS OF PIPE. |
| | |
| | 3. CLEARLY INDICATE THE TYPE OF GAS, (LP OR NATURAL) |
| | BEING USED. PER FBC-2004 FUEL GAS SECTION 401.1 SCOPE. |
| | |
| | 4. SHOW THE DISTANCE FROM THE POINT OF |
| | DELIVERY, (METER), TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| | FBC-2004 FUEL GAS CODE APPENDIX A - USE |
| | OF CAPACITY TABLES A.3.1(4). |
| | *NOTE: PLEASE REFERENCE COMMENT #1 AND COMPLY. |
| | |
| | 5. SUBMIT MANUFACTURE SHEETS FOR THE MP REGULATOR, POOL |
| | HEATER AND GRILLS TO VERIFY COMPLIANCE WITH STANDARDS |
| | NFPA 54, NFPA 58, AND THE FBC-2004 FUEL GAS CODE SEC |
| | 402.2. MANUFACTURE SHEETS SHALL CLEARLY INDICATE THE |
| | MAKE, MODEL NUMBER, BTU LOAD CAPACITY, AND A LISTING |
| | FROM A NATIONALLY RECOGNIZED TESTING LABORATORY SUCH AS |
| | CSA, AGA, OR UL. |
| | |
| | 6. THE VALUE ON THE PERMIT APPLICATION APPEARS LOW. THE |
| | VALUE ON THE PERMIT APPLICATION MUST INCLUDE THE TOTAL |
| | COST OF LABOR, MATERIALS AND THE THREE GAS APPLIANCES. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF A NATIONAL CONSTRUCTION COST ANALYSIS |
| | (MARSHALL-SWIFT, MEANS, ECT...) ADJUST THE VALUE AT THE |
| | PERMIT CLERK'S DESK AND PAY THE DIFFERENCE IN FEES |
| | PRIOR TO RESUBMITTING. PER (W.P.B. AS AMENDED) SECTION |
| | 108.3 BUILDING PERMIT VALUATION. |
| | NOTE: IF APPLIANCES ARE NOT BEING INSTALLED AT THIS |
| | TIME THEN DESIGNATE THE APPLIANCES AS "FUTURE" AND |
| | INDICATE THAT THEY WILL BE CAPPED GAS TIGHT PER |
| | FBC-2004 FUEL GAS SECTION 404.12 OUTLET CLOSERS. |
| | |
| | 7. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING |
| | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE |
| | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE |
| | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER |
| | SECTION *106.3.4.3. |
| | *NOTE: PLEASE CLEARLY PRINT THE NAME OF THE PERSON WHO |
| | IS TAKING RESPONSIBILITY OF THE ISOMETRIC WHOSE |
| | SIGNATURE APPEARS ON THE PLANS. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | PHONE= (561) 805-6730 |
| | FAX= (561) 805-6731 |
| | E-MAIL= [email protected] |