2009-02-10 17:16:09****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 COMMENTS FROM FIRST REVIEW:
  
 1. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED
 PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD. PLEASE CALL
 561-233-5025 FOR MORE INFORMATION. THE PLANS MUST BE
 STAMPED AND THE RECEIPT IS TO BE INCLUDED WITH THE
 PERMIT APPLICATION.
  
 NOT COMPLETED AT THIS TIME. PLEASE NOTE THAT THIS ITEM
 MUST BE DONE PRIOR TO PERMIT ISSUANCE, BUT MAY BE DONE
 AFTER ALL PLAN REVIEWS HAVE BEEN COMPLETED (NO RESUB
 FEE IF SUBMITTAL IS FOR IMPACT FEE ONLY, AND HAS PASSED
 ALL TRADES).
  
 2-25. ADDRESSED.
  
 27. FBC13-101.3, BUILDING SHALL COMPLY WITH FBC13-4.
  
 3RD REVIEW, TOTAL SF AREA TOTAL 46709, BUT THE PLANS
 STATE THE RENOVATED AREA IS 44714. PLEASE REVISE.
  
 28. ADDRESSED.
  
 29. PROVISO - SHOP DRAWINGS FOR THE FIRE RATED GLAZING
 WILL BE REQUIRED PRIOR TO INSTALLATION.
  
 30-35. ADDRESSED (SEPARATE PERMIT REQUIRED FOR
 AWNINGS).
  
 36. SOILS REPORT, ALL INFORMATION REQUIRED BY
 FAC61G15-23.002(2) REQUIRED (CERTIFICATE OF
 AUTHORIZATION). PLEASE NOTE THAT THIS REQUIREMENT HAS
 RECENTLY BEEN REVISED.
  
 37. SEE ENERGY CALCS; NO DOORS SHOWN, ICE RINK FLOOR IS
 SHOWN AS CARPET. PLEASE REVISE THESE ITEMS AND CHECK
 ALL INFORMATION ON THE ENERGY CALC INPUT DATA REPORT.
  
 2ND REVIEW, THIS HAS BEEN ADDRESSED. HOWEVER, PLEASE
 EXPLAIN THE ROOF R VALUE; R19 BATT INSULATION IS SHOWN
 (MULTIPLIED BY BTU) THAT IT HAS AN R VALUE OF 30.
 PLEASE CLARIFY HOW R30.3 WILL BE ACHIEVED.
 3RD REVIEW, THIS HAS NOT BEEN REVISED OR EXPLAINED.
 FEEL FREE TO CONTACT ME VIA EMAIL OR TELEPHONE TO
 CLARIFY THIS NUMBER (R30). ALSO PLEASE NOTE THAT DOORS
 AND WINDOWS HAVE NOW BEEN REMOVED FROM THE ENERGY
 CALCS. PLEASE CONFIRM THAT ALL BUILDING DATA IS CORRECT
 PRIOR TO RESUBMITTING.
  
 38. PLEASE HAVE THE ARCHITECT SIGN THE ENERGY CALC,
 FBC103.1.1.1. IF A TYPED NAME IS PROVIDED IN LIEU OF A
 SIGNATURE, PLEASE CONFIRM THAT ALL RELEVANT INFORMATION
 (INCLUDE THE EXISTING COMPONENTS, SUCH AS EXISTING
 INSULATION) IS INCLUDED.
  
 2ND REVIEW, NOT ADDRESSED. ARCHITECT?S RESPONSE LETTER
 STATES HE WILL COMPLY. PLEASE REVISE ENERGY CALCS PER
 REVIEW COMMENTS AND, WHEN RESUBMITTING, CONFIRM THAT
 ARCHITECT HAS SIGNED THE APPROPRIATE LINE.
 3RD REVIEW, NOT ADDRESSED. SIGNATURE NOT INCLUDED,
 PRINTED NAME NOT INCLUDED.
  
 39-40. ADDRESSED.
  
 41. PROVISO - AT RISK (EXTERIOR PERMIT NOT YET ISSUED)
  
 42-44. ADDRESSED.
  
 45. PROVISO - LOUVER PRODUCT APPROVALS REQUIRED,
 REVIEWED BY DESIGNER OF RECORD
  
 46. ADDRESSED.
  
 47. PROVISO - E3, E4, LS01 MISSING STROBES IN SOME
 BATHROOMS - REVISE ACCORDINGLY PRIOR TO FIRE ALARM
 INSTALLATION
  
 48. ADDRESSED.
  
 NEW COMMENTS:
  
 49. INFORMATIONAL ONLY; LEVEL III ALTERATION DECLARED.
 SEE DEFINITION OF LEVEL III; THIS IS DEFINED AS HAVING
 A WORK AREA OVER 50% OF BUILDING AREA, BUT THE NEW
 INFORMATION REGARDING BUILDING AREA SHOWS THIS IS LESS
 THAN 50%. PLEASE NOTE THAT IT IS ACCEPTABLE TO EXCEED
 CODE COMPLIANCE; HOWEVER, IF LEVEL III IS DECLARED, IT
 SHALL BE ENFORCED BOTH IN PLAN REVIEW AND IN THE FIELD
 (INSPECTIONS).
  
  