| 2008-10-01 10:57:38 | BUILDING PLAN REVIEW |
| | PERMIT: 08090596 |
| | ADD: 5707 S. DIXIE HIGHWAY #B |
| | CONT: P&T CONSTRUCTION, INC. |
| | TEL: (561)833-0614 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 10-1-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 3) SHEET A2 CONFERENCE ROOM AND OFFICE #1 DOORS SHALL |
| | MEET THE REQUIREMENTS OF FBC SECTION 11-4.13.6 |
| | MANEUVERING CLEARENCES AT DOORS. MINIMUM MANEUVERING |
| | CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC OR |
| | POWER-ASSISTED SHALL BE AS SHOWN IN FIG. 25. |
| | |
| | 4) SINKS: 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE |
| | MOUNTED WITH THE COUNTER NO HIGHER THAN 34" ABOVE THE |
| | FINISH FLOOR. |
| | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" |
| | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. |
| | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT |
| | LEAST 30 INCHES BY 48 INCHES COMPLYING WITH SECTION |
| | 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW |
| | FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN |
| | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 |
| | INCHES UNDERNEATH THE SINK. PROVIDE ELEVATION DETAIL |
| | DRAWINGS SHOWING THESE REQUIREMENTS. |
| | |
| | 5) SHEET A3 IS MISSING THE SEAL, SIGNATURE AND DATE OF |
| | THE DESIGN PROFESSIONAL. THE SEAL OF THE ENGINEER IS |
| | NOT LEGIBLE. 106.1.3* THE SEAL SHALL BE OF SUFFICIENT |
| | CLARITY FOR OUR RECORDS MANAGEMENT PROGRAM. TITLE BLOCK |
| | WITH THE INFORMATION SPECIFIED PER 61G1-16.004 FAC |
| | SHALL BE PRESENT ON DRAWINGS ISSUED BY THE RESPONSIBLE |
| | ARCHITECT AND MUST, AT A MINIMUM CONTAIN |
| | 1) FIRM NAME, ADDRESS, AND TELEPHONE # |
| | 2) FIRM LICENCE # |
| | 3) NAME OF PROJECT |
| | 4) DATE PREPARED |
| | 5) A SPACE FOR SIGNATURE & DATED SEAL |
| | 6) A SPACE FOR PRINTED NAME OF PERSON SEALING THE |
| | DOCUMENT |
| | |
| | 6) THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | INCLUDING STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, |
| | INTERIOR FINISHES, MARKETING COST, OVERHEAD AND PROFIT |
| | EXCLUDING LAND VALUE. OUR VALUARTION REFERENCE IS ICC |
| | (BVD) MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |