| 2008-12-13 15:33:42 | REVIEW #: 2ND |
| | ACTION: PASS W/ PROVISO |
| | |
| | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS |
| | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH |
| | |
| | COMMENTS 1,3,4 AND NOTE HAVE BEEN ADEQUATELY ADDRESSED. |
| | PERMIT MAY BE ISSUED WITH THE FOLLOWING PROVISO: |
| | |
| | *******************PROVISO********************* |
| | EXHAUST FAN EXPOSED TO WIND SHALL BE DESIGNED AND |
| | INSTALLED TO RESIST WIND PRESSURES IN ACCORDANCE WITH |
| | FBCM 301.13 AND FBCB 1609. |
| | PROVIDE MANUFACTURER'S DATA FOR WIND RESISTANCE OR A |
| | RATIONAL ANALYSIS FROM A FLORIDA LICENSED STRUCTURAL |
| | ENGINEER CERTIFYING THE PROPOSED FAN IS DESIGNED FOR |
| | WIND RESISTANCE BASED ON THE LOCATION INSTALLED |
| | (ELEVATION, EXPOSURE CATEGORY AND WIND IMPORTANCE |
| | FACTOR) AS DETERMINED BY FBCB SECTION 1609. |
| | |
| | NOTE: DESIGNER'S WRITTEN RESPONSE INDICATES NO FAN |
| | WHICH IS DESIGNED FOR WIND RESISTANCE COULD BE FOUND. |
| | THERE IS AT LEAST ONE AND POSSIBLY MORE EXHAUST FAN |
| | MANUFACTURERS WITH A LINE OF FANS DESIGNED FOR WIND |
| | RESISTANCE. THIS OFFICE IS PROHIBITED BY POLICY FROM |
| | RECOMMENDING SPECIFIC BRANDS OR MANUFACTURERS. A SEARCH |
| | OF MIAMI-DADE'S NOA DATABASE MAY PROVIDE ADDITIONAL |
| | GUIDANCE IN YOUR SEARCH FOR A CODE COMPLAINT OUTDOOR |
| | APPLIANCE. AN NOA IS NOT SPECIFICALLY REQUIRED FOR |
| | OUTDOOR APPLIANCES. HOWEVER, THE DATA PROVIDED IN A |
| | CURRENT NOA MAY BE USED AND WOULD BE ACCEPTED BY THIS |
| | AHJ AS A DEMONSTRATION OF CODE COMPLIANCE. |
| | |