| Date |
Text |
| 2008-09-29 09:18:16 | PLUMBING PLAN REVIEW: |
| | DENIED: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. |
| | |
| | 1. PLUMBING SHEET: CLEARLY INDICATE IF THE NEW DROP IN |
| | TUB IS GOING TO BE A WHIRLPOOL BATHTUB (JACUZZI) AND IF |
| | IT IS CLEARLY INDICATE THAT ACCESS SHALL BE PROVIDED TO |
| | THE PUMP. PER FBC-2004 PLUMBING SECTION 421.2 |
| | INSTALLATION. |
| | |
| | 2. PLUMBING SHEET: CLEARLY INDICATE THAT THE NEW SHOWER |
| | VALVE SHALL BE A BALANCED PRESSURE, THERMOSTATIC OR |
| | COMBINATION BALANCED-PRESSURS/THERMOSTATIC VALVES THAT |
| | CONFORM TO THE REQUIREMENTS OF ASSE 1016. THE SHOWER |
| | VALVE SHALL BE EQUIPPEDWITH A MEANS TO LIMIT THE |
| | MAXIMUM SETTING OF THE VALVE TO 120 DEGREES (F), WHICH |
| | SHALL BE FIELD ADJUSTED IN ACCORDANCE TO MANUFACTURER'S |
| | INSTRUCTIONS. PER FBC-2004 PLUMBING SECTION 424.3 |
| | SHOWER VALVES. |
| | |
| | 3. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING |
| | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE |
| | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE |
| | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER |
| | (W.P.B. AS AMENDED) SECTION *106.3.4.3. |
| | *NOTE: CLEARLY PRINT THE NAME OF THE PERSON WHOSE |
| | SIGNATURE APPREARS ON THE PLAN SHEETS THAT IS TAKING |
| | RESPONSIBILITY FOR THE PLAN SHEETS. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | PHONE= (561) 805-6730 |
| | FAX= (561) 805-6731 |
| | E-MAIL= [email protected] |