| Date |
Text |
| 2009-01-02 10:45:54 | FAILED |
| | |
| | PROVIDE RESPONSES IN WRITING: |
| | |
| | 1) AS STATED IN THE 1ST REVIEW, THIS PERMIT REQUIRES A |
| | MINOR PD AMENDMENT AND FORMAL SITE PLAN APPROVAL PRIOR |
| | TO ZONING PASSING THE PERMIT. NEITHER OF THESE HAVE |
| | BEEN GRANTED. |
| | |
| | 2) ZONING COMMENTS: |
| | |
| | A. PARKING DETAILS MEETING CITY OF WEST PALM BEACH |
| | STANDARDS ARE REQUIRED ON THE PLANS. SPECIFIC ISSUE - |
| | WHEEL STOP LOCATION NOT TWO (2) FEET FROM THE HEAD OF |
| | THE SPACE. NOTE THE DETAIL DIMENSIONS DO NOT MATCH THE |
| | DIMENSIONS ON THE PLAN. |
| | B. THE NEW DUMPSTER ENCLOSURE SHOW ON THE PLANS DOES |
| | NOT MEET CITY SIZE OR LANDSCAPE STANDARDS. NOTE THE |
| | DETAIL DIMENSIONS DO NOT MATCH THE DIMENSIONS ON THE |
| | PLAN. |
| | C. D-TYPE CURBING SHALL BE USED TO PROTECT THE |
| | LANDSCAPE AREAS FROM VEHICULAR ENCROACHMENT ALONG THE |
| | DRIVE AISLES. THIS IS NOT INDICATED ON THE PLANS. |
| | D. THE SITE AND THE LANDSCAPE PLANS DO NOT MATCH. |
| | SPECIFICALLY IN THE NORTHWEST CORNER OF THE LIMITS OF |
| | WORK. |
| | E. THE AMERICANS WITH DISABILITIES ACT (ADA) REQUIRES |
| | THAT IF COVERED PARKING IS PROVIDED, THEN COVERED ADA |
| | PARKING SHALL BE PROVIDED AS WELL. EITHER SHOW WHERE |
| | THERE CURRENTLY EXISTS COVERED ADA PARKING ON THE |
| | CHRISTIAN CONVENTION CENTER CAMPUS, OR PROVIDE A |
| | COVERED ADA SPACE IN THE NEW COVERED PARKING AREA. IF |
| | ADA SPACE IS REQUIRED, THE DETAILS SHALL BE PROVIDED. |
| | F. WHAT ARE THE DOTS SHOWN IN THE DRIVE AISLE? ARE |
| | THESE COLUMNS OR STRAY MARKS. COLUMNS ARE NOT ALLOWED, |
| | STRAY MARKS SHALL BE REMOVED. |
| | |
| | 3) LANDSCAPE COMMENTS: |
| | |
| | A. SHEETS LA.01 AND SP.01 WITH THE LATEST REVISION DATE |
| | OF 10/31/08 ARE INCONSISTENT. THERE IS AN APPARENT |
| | WALKWAY SHOWN ON ONE PLAN AND A RETAINING WALL ON THE |
| | OTHER. |
| | B. SHEET LA.01 THAT WAS SUBMITTED WITH THE ?TREE |
| | ALTERATION PERMIT? IS DIFFERENT FROM SHEET LA.01 THAT |
| | WAS MOST RECENTLY SUBMITTED AND YET SHARES THE SAME |
| | REVISION DATE. THERE WERE TWO (2) ALEXANDER PALMS SHOWN |
| | ON THE TREE ALTERATION PERMIT SET THAT WERE TO BE |
| | RELOCATED AND THEN REPLANTED AFTER CONSTRUCTION. THESE |
| | TWO (2) PALMS WERE NOT SHOWN ON THE MOST RECENT |
| | SUBMITTAL AND THREE (3) UNIDENTIFIED UNDERSTORY TREES |
| | WERE SHOWN. A PALM PLANTING DETAIL SHOWN ON THE |
| | ORIGINAL SET OF PLANS WAS MISSING FROM THE MOST RECENT |
| | SET. |
| | C. PURSUANT TO SECTION 94-444(B), WALLS OF THE DUMPSTER |
| | ENCLOSURE SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES |
| | PLANTED AT TWO FOOT INTERVALS. A HEDGE WAS SHOWN ON |
| | ONLY ONE SIDE OF THE PROPOSED ENCLOSURE. IT IS REQUIRED |
| | ON THREE (3) SIDES. |
| | D. ALL PROPOSED LIGHTING SHALL BE SHOWN ON THE |
| | LANDSCAPE PLAN TO AVOID CONFLICTS. |
| | E. PURSUANT TO SECTION 94-442(G), IN KEEPING WITH |
| | XERISCAPE GUIDELINES, THE PALMS THAT SURROUND THE PLAZA |
| | SHOULD BE UNDER PLANTED AND CONTAINED WITHIN A PLANT |
| | BED. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
| | |