| 2008-09-30 11:17:56 | BUILDING PLAN REVIEW |
| | PERMIT: 08090363 |
| | ADD: 701 BELVEDERE RD |
| | CONT: LCI CONSTRUCTION |
| | TEL: (561)307-4935 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, |
| | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: |
| | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS |
| | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE REVISE SHEET |
| | A1 TO THE CURRENT 2007 SUPPLEMENTS. |
| | |
| | 1D) SHETT A-1 UNDER THE HEADING BUILDING DATA WHERE THE |
| | CURRENT CODES ARE LISTED, PLANS FAIL TO IDENTIFY THE |
| | 2004FBC EXISTING BUILDING WITH 2007 SUPPLEMENTS NOR THE |
| | LEVEL OF ALTERATION HAS NOT BEEN DECLARED BY THE DESIGN |
| | PROFESSIONAL 2004 FBC EXIST. SECTION 301.5. |
| | |
| | 2) SHEET A1 INDICATES A SECTION 4 OF A4 PLANS DO NOT |
| | PROVIDE WHAT THE HEIGHT DIFFERENCE IS IN THE FRONT CURB |
| | AND ACCESSIBLE RAMP AREAS. IT CAN NOT BE DETERMINED IF |
| | THERE IS A GREATER THAN 6" DIFFERENCE IN GRADE THAT |
| | ENACT 11.4.8.5. HANDRAILS: IF A RAMP HAS A RISE GREATER |
| | THAN 6" OR A HORIZONTAL PROJECTION GREATER THAN 72", |
| | THEN IT SHALL HAVE HANDRAILS ON BOTH SIDES. |
| | |
| | 3) SHEET A-1 WALK IN COOLERS & FREEZERS THE TOTAL |
| | SQUARE FOOTAGE OF THE WALK-IN UNITS IS APPROX 417 SQ |
| | FT. 2603.4.1.3 LIMITS THE THE AGGREGATE FLOOR AREA TO |
| | 400 SQ FT. PLEASE MODIFY, 2603.4.1.3. |
| | NOTE THAT THE ACTUAL COOLER AND MECHANICAL EQUIPMENT |
| | WILL REQUIRE A SEPERATE PERMIT WHERE AS THE REMAINDER |
| | OF THE REQUIREMENTS OF 2603.4.1.3 WILL NEED TO BE MET. |
| | SEPERATE REVIEWS WITH ASSOCIATED FEES WILL THEN OCCUR. |
| | |
| | 4) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE |
| | 2 COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS |
| | ARE AS FOLLOWS: |
| | 4A) STORM SHUTTERS- THE REPORT SUBMITTED 02-0809.02 |
| | EXPIRED 10/10/07 WILL REQUIRE NEW REPORT RULE 9B-72 |
| | (31) ( E) |
| | 4B) PRE-ENGINEERED A/C STANDS RULE 9B-72(31)(G) |
| | |
| | 5) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 6) PLEASE NOTE: 104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR |
| | WIND-BORNE DEBRIS IMPACT PROTECTION QUESTION# 13 |
| | RECOGNIZING SUCH CONCERNS AS ABSENTEE OWNERS, OR CASES |
| | WHERE LONGER TIME & EFFORT IS NECESSARY TO SECURE |
| | SHUTTERS A COMPLETE INSTALLATION INSTALLATION SCHEDULE |
| | FOR SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE |
| | HURRICANE. PROVIDE STORM PANEL INFORMATION WITH |
| | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| | GLAZING. |
| | |
| | FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 & |
| | EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE |
| | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| | WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE |
| | PLAN REVIEW AND PERMIT ISSUANCE. |
| | A SAMPLE STORM SHUTTER SCHEDULE IS ATTACHED. |
| | |
| | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE |
| | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, |
| | SECTION 104.6 OF THE FLORIDA BUILDING CODE, BUILDING, |
| | CHAPTER 1, ADMINISTRATIVE CODE2004 EDITION AS AMENDED |
| | BY THE CITY OF WEST PALM BEACH, PROVIDES THE ABILITY |
| | FOR THE BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR |
| | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION |
| | OF EXISTING BUILDINGS. |
| | |
| | 7) BOTH SHEETS A1 & A7 INDICATE A T8 FUTURE DEAL DWAWER |
| | BUT NO INFORMATION HAS BEEN PROVIDED PRODUCT |
| | INFORMATION, THE SECURING INTO THE STRUCTURAL SHELL OF |
| | THE BUILDING.1609.6.1.2. COMPONENTS AND CLADDING. |
| | |
| | 8) SHEET A-1 MISSING THE REQUIRED 18" BETWEEN THE WATER |
| | COOLER AND LATCH SIDE OF THE RESTROOM DOOR. 11-4.13.6 |
| | MANEUVERING CLEARENCES AT DOORS. MINIMUM MANEUVERING |
| | CLEARANCES |
| | AT DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL |
| | BE AS SHOWN IN FIG. 25. THE FLOOR OR GROUND AREA WITH |
| | IN THE REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL. |
| | |
| | 9) SHEET A4 DETAIL 2 THE COUNTER HEIGHT IS 36" BUT THE |
| | COUNTER HEIGHT SHOULD BE 34" SECTION 11-5.2. |
| | |
| | 10) THE ENRGY CALCULATIONS INDICATE THE USE OF 3" |
| | ICYNENE INSULATION AT THE CONCRETE DOUBLE TEE ROOF |
| | SYSTEM PROVIDING A R VALUE OF 12.3. PLEASE REVIEW |
| | 2603.5.2 AND REQUIRED THERMAL BARRIER MEETING THE |
| | PROVISIONS OF SECTION 2603.4 . |
| | |
| | 11A) THE ENERGY CALCULATIONS ALSO INDICATE A R-VALUE OF |
| | 5.73 FOR A CONCRETE FLOOR WITH CARPET AND RUBBER |
| | PADDING. 804.5.1 MINIMUM CRITICAL RADIANT FLUX. |
| | INTERIOR FLOOR FINISH IN VERTICAL EXITS, EXIT |
| | PASSAGEWAYS AND EXIT ACCESS CORRIDORS SHALL NOT BE LESS |
| | THAN CLASS I IN GROUPS I-2 AND I-3 AND NOT LESS THAN |
| | CLASS II IN GROUPS A, B, E, H, I- 4, M, R-1, R-2 AND S. |
| | IN ALL OTHER AREAS, THE INTERIOR FLOOR FINISH SHALL |
| | COMPLY WITH THE DOC FF-1 ?PILL TEST? (CPSC 16 CFR, PART |
| | 1630). |
| | |
| | |
| | 11B) 11-4.5.3 CARPET . IF CARPET OR CARPET TILE IS USED |
| | ON A GROUND OR FLOOR SURFACE, THEN IT SHALL BE SECURELY |
| | ATTACHED; HAVE A FIRM CUSHION, PAD, OR BACKING, OR NO |
| | CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP, |
| | LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. THE |
| | MAXIMUM PILE THICKNESS SHALL BE ? INCH (13 MM) [SEE |
| | FIGURE 8 (F)]. EXPOSED EDGES OF CARPET SHALL BE |
| | FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE |
| | ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM |
| | SHALL COMPLY WITH SECTION 11-4.5.2 . PLEASE PROVIDE |
| | MANUFACTURERS INFORMATION ON CARPET AND PAD. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |