| Date |
Text |
| 2008-10-06 16:56:59 | BUILDING PLAN REVIEW |
| | PERMIT: 08090306 |
| | ADD: 525 OKEECHOBEE BLVD SUITE 1050 |
| | CONT: BUTLER |
| | TEL: (561)644-3579 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION, PLEASE |
| | CORRECT PLANS INDICATE BY FINAL |
| | COVERSHEET. |
| | |
| | 1E) : PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS COVER SHEET DOES NOT |
| | INCLUDE 2007 SUPPLEMENTS, PLEASE CORRECT. |
| | |
| | 2) SHEET A-1 DOOR NOTE # 5 INDICATES THE USE OF CARD |
| | READERS AND ELECTRONIC LOCKS, PLANS FAIL TO INDICATE IF |
| | THE LOCKS AUTOMATICLLY SET TO A FAIL SAFE OPEN POSITION |
| | WITH LOSS OF POWER. 1008.1.3.4. |
| | |
| | 3) SHEET A-1 TENANT SEPERATION WALLS ARE A 1 HR RATED |
| | WALL. THE DOOR SCHEDULE DOES NOT INDICATE OPENING |
| | PROTECTION FOR 2 OF THE 3 ENTRY DOORS. DOOR# 1029 UNDER |
| | REMARKS DOES INDICATE 20 MINUTE DOOR WITH CLOSERE. |
| | DOOR# 1001 INDICATES HOLD OPEN DEVICES AND DOOR CLOSERS |
| | BUT NOT A RATED DOOR AND DOOR# ETR UNDER REMARKS ONLY |
| | INDICATES AN ELETRIC STRIKE. NO MENTION OF A DOOR |
| | CLOSER OR FIRE RATING OF DOOR AND JAMB. OPENING |
| | PROTECTIVES TABLE 715.3./708.1. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |