2008-10-06 16:56:59BUILDING PLAN REVIEW
 PERMIT: 08090306
 ADD: 525 OKEECHOBEE BLVD SUITE 1050
 CONT: BUTLER
 TEL: (561)644-3579
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION, PLEASE
 CORRECT PLANS INDICATE BY FINAL
 COVERSHEET.
  
 1E) : PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS COVER SHEET DOES NOT
 INCLUDE 2007 SUPPLEMENTS, PLEASE CORRECT.
  
 2) SHEET A-1 DOOR NOTE # 5 INDICATES THE USE OF CARD
 READERS AND ELECTRONIC LOCKS, PLANS FAIL TO INDICATE IF
 THE LOCKS AUTOMATICLLY SET TO A FAIL SAFE OPEN POSITION
 WITH LOSS OF POWER. 1008.1.3.4.
  
 3) SHEET A-1 TENANT SEPERATION WALLS ARE A 1 HR RATED
 WALL. THE DOOR SCHEDULE DOES NOT INDICATE OPENING
 PROTECTION FOR 2 OF THE 3 ENTRY DOORS. DOOR# 1029 UNDER
 REMARKS DOES INDICATE 20 MINUTE DOOR WITH CLOSERE.
 DOOR# 1001 INDICATES HOLD OPEN DEVICES AND DOOR CLOSERS
 BUT NOT A RATED DOOR AND DOOR# ETR UNDER REMARKS ONLY
 INDICATES AN ELETRIC STRIKE. NO MENTION OF A DOOR
 CLOSER OR FIRE RATING OF DOOR AND JAMB. OPENING
 PROTECTIVES TABLE 715.3./708.1.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved