Plan Review Notes
Plan Review Notes For Permit 08090189
Permit Number 08090189
Review Stop P
Sequence Number 1
Notes
Date Text
2008-09-11 11:54:06PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THE SUBMITTED IRRIGATION PLANS ARE NOT INDICATING
 THE REQUIRED RAIN SHUT OFF DEVICE (RAIN SENSOR). THIS
 DEVICE MUST BE CLEARLY INDICATED ON THE IRRIGATION
 PLANS AS WELL AS ITS SYMBOL ON THE IRRIGATION LEGEND.
 THE AUTOMATIC IRRIGATION CONTROLLER SHALL BE CAPABLE OF
 INCORPORATING A RAIN SHUT OFF DEVICE TO OVERRIDE THE
 IRRIGATION CYCLE WHEN ADEQUATE RAINFALL HAS OCCURED, AS
 REQUIRED BY FLORIDA STATUTES, SECTION 373.62. THE RAIN
 SWITCH SHALL BE PLACED ON A STATIONARY STRUCTURE
 MINIMUM OF 5-FOOT (1524MM) CLEARANCE FROM OTHER OUTDOOR
 EQUIPMENT, FREE AND CLEAR OF ANY TREE CANOPY OR OTHER
 OVERHEAD OBSTRUCTIONS, AND ABOVE THE HEIGHT OF THE
 SPRINKLER COVERAGE.
  
 2. CLEARLY INDICATE THAT THE 1" BACKFLOW PREVENTER FOR
 THE IRRIGATION SUPPLY IS BEING INSTALLED BY A LICENSED
 PLUMBING CONTRACTOR. PER FLORIDA STATUTES 489.105
 (3)(M) PLUMBING CONTRACTOR.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved