| 2008-09-09 10:33:34 | **ZONING FAILED** |
| | |
| | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. |
| | |
| | 2. STATE EXACT SCOPE OF WORK ON BUILDING PERMIT |
| | DESCRIPTION, I.E., ANY ADDITIONS (TERRACE/CHIMNEY, IF |
| | APPLICABLE), DEMOLITIONS, LAYOUT CHANGE, INCREASING THE |
| | HEIGHT OF THE STRUCTURE, ETC. |
| | |
| | 3. THE BOUNDARY SURVEY THAT WAS SUBMITTED INCLUDES THE |
| | PROPERTY NEXT DOOR AS PART OF THE SUBJECT SITE. THE PBC |
| | PROPERTY APPRAISERS RECORDS SHOW THAT THESE PARCELS ARE |
| | SEPARATE. PLEASE CLARIFY. |
| | |
| | 4. INDICATE ON SURVEY THE SETBACK DIMENSIONS FROM ANY |
| | EXTERIOR IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. |
| | |
| | 5. PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE |
| | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE |
| | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT |
| | BUILDING FACADE). |
| | |
| | INDICATE WHETHER THE PROPOSED DRIVEWAY BRICK PAVERS ARE |
| | SEALED OR UNSEALED AND WHETHER THEY ARE SET IN SAND OR |
| | OVER CONCRETE. PURSUANT TO THE CITY OF WEST PALM BEACH |
| | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION |
| | 94-482: REQUIRED OFF-STREET PARKING SPACES FOR LESS |
| | THAN FOUR RESIDENTIAL DWELLING UNITS SHALL BE LOCATED |
| | ON THE PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. |
| | REQUIRED PARKING MAY BE LOCATED IN A FRONT YARD; |
| | HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT |
| | OF THE FRONT YARD AREA MUST BE LANDSCAPED. |
| | |
| | 6. INDICATE THE HEIGHT OF BOTH BUILDINGS ON ELEVATION |
| | PLANS. PURSUANT TO THE ZLDR, SECTION 94-72(A)(3): |
| | MAXIMUM BUILDING HEIGHT IN SINGLE FAMILY LOW DENSITY |
| | (SF7) RESIDENTIAL DISTRICT IS 30 FEET AND PURSUANT TO |
| | SECTION 94-304(B)(4), ACCESSORY STRUCTURES SHALL NOT |
| | EXCEED 25 FEET. |
| | |
| | 7. CLARIFY WHETHER THE CHIMNEY IS EXISTING OR PROPOSED. |
| | IF PROPOSED, PURSUANT TO THE ZLDR, SECTION 305(B)(10): |
| | CHIMNEYS MAY NOT PROJECT NO MORE THAN 18 INCHES INTO |
| | ANY SETBACK. |
| | |
| | SHEET NO.: A203 INDICATES THE TOTAL HEIGHT INCLUDING |
| | THE CHIMNEY IS 34 FEET - 6 INCHES. PURSUANT TO THE |
| | ZLDR, SECTION 306(A): CHIMNEYS MAY EXCEED DISTRICT |
| | HEIGHT REQUIREMENTS BY ONLY TEN (10) PERCENT. |
| | |
| | 8. IF PROPOSING TO INSTALL OR RELOCATE ANY A/C |
| | EQUIPMENT, INDICATE SETBACK DIMENSIONS TO ALL PROPERTY |
| | LINES. PURSUANT TO THE ZLDR, SECTION 94-305(B)(4): |
| | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET |
| | INTO A REQUIRED SETBACK. |
| | |
| | 9. CORRELATE ALL SITE PLAN CHANGES. |
| | |
| | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY |
| | GENERATE ADDITIONAL COMMENTS. |
| | |