| 2008-09-20 09:06:37 | |
| | |
| | DENIED |
| | |
| | 1) PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL |
| | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 |
| | AMENDMENTS |
| | |
| | 2) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION,NATURE, AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 FBC* |
| | |
| | 3) PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4 |
| | FBC. PLEASE NOTE THE 2006 AMENDMENTS TO THE 2004 FBC |
| | REQUIRE BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN |
| | THAT IS DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS |
| | OPEN GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF |
| | 600 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C |
| | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND |
| | PRESSURES ACCORDINGLY |
| | |
| | 2) PER R301 FBC RES. THE FOLLOWING DESIGN CRITERIA IS |
| | REQUIRED ON THE CONSTRUCTION DOCUMENTS SUBMITTED FOR |
| | PERMIT, BUILDINGS AND STRUCTURES, AND ALL PARTS |
| | THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT ALL |
| | LOADS, INCLUDING DEAD LOADS, LIVE LOADS, ROOF LOADS, |
| | FLOOD LOADS AND WIND LOADS AS PRESCRIBED BY THIS CODE. |
| | THE CONSTRUCTION OF BUILDINGS AND STRUCTURES SHALL |
| | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH |
| | CAPABLE OF TRANSFERRING ALL LOADS FROM THEIR POINT OF |
| | ORIGIN THROUGH THE LOAD-RESISTING ELEMENTS TO THE |
| | FOUNDATION. |
| | |
| | 3) THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THIS |
| | SHALL INCLUDE ROOFING MATERIALS, DOORS,WINDOWS, |
| | STRAPS/CONNECTOR, ETC. |
| | |
| | 4) PER SECTION 1609.1.4 FBC OPENING PROTECTION IS |
| | REQUIRED, ALL GLAZED OPENING SHALL MEET LARGE MISSILE |
| | IMPACT TEST |
| | |
| | 5) ADDITIONAL PERMITS WILL BE REQUIRED FOR ELECTRICAL |
| | AND ROOFING |
| | |
| | 6) PROVIDE ROOF FRAMING INFORMATION AND LAYOUT, IS THIS |
| | ROOF FRAMED OF TRUSS,IF TRUSSES ARE USED SUBMIT 2 |
| | COPIES OF ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH |
| | R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE |
| | INSTALLATION. |
| | |
| | 7) PROVIDE MIN ROOF SHEATHING ATTACHMENT |
| | PER R803.2.3.1 FBC RES. |
| | |
| | 8) DRAWINGS INCOMPLETE, ELEVATIONS AND PLAN VIEWS DO |
| | NOT RELATE NO BAY WINDOWS SHOWN ON PLAN. NO PORCH ROOF, |
| | PROVIDE WINDOW AND DOOR SIZES, OVERALL DIMENSIONS. MEAN |
| | ROOF HEIGHT, ETC. |
| | |
| | 9) WHEN COMPLETE DRAWINGS AND PRODUCT APPROVALS ARE |
| | SUBMITTED FURTHER COMMENTS MAY ARISE |
| | |
| | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006&2007 |
| | AMENDMENTS |
| | FBC* = WEST PALM BEACH ADMINISTRATIVE |
| | AMENDMENTS TO FBC |
| | FAC = FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | FBC RES. = FLORIDA BUILDING CODE RESIDENTIAL 2004 |
| | W/2006&2007 AMENDMENTS |
| | |
| | BLDG PLAN REVIEW |