| Date |
Text |
| 2009-10-01 10:37:31 | BUILDING PLAN REVIEW |
| | PERMIT: 08080616 |
| | ADD: 8190 OKEECHOBEE BLVD |
| | CONT: HALLMARK & SONS |
| | TEL: (561)644-3498 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION REVIEW |
| | ACTION: DENIED |
| | OCT. 01/ 2009 |
| | 1) COMPLIED. |
| | 2) PLEASE NOTE ZONING REVIEWERS COMMENTS DEALING WITH |
| | ACCESSIBLE ROUTE TO THE RIGHT OF WAY. 11-4.1.2 |
| | ACCESSIBLE SITE AND EXTERIOR FACILITIES: NEW |
| | CONSTRUCTION. |
| | THIS EDITION OF THE CODE DOES NOT APPLY TO BUILDINGS, |
| | STRUCTURES, OR FACILITIES WHICH WERE EITHER UNDER |
| | CONSTRUCTION OR UNDER CONTRACT FOR CONSTRUCTION ON |
| | OCTOBER 1,1997. |
| | NOTHING IN THIS CODE SHALL BE CONSTRUED TO RELIEVE THE |
| | OWNER OF ANY BUILDING, STRUCTURE OR FACILITY FROM THE |
| | DUTY TO PROVIDE VERTICAL ACCESSIBILITY TO ALL LEVELS |
| | ABOVE AND BELOW THE OCCUPIABLE GRADE LEVEL, REGARDLESS |
| | OF WHETHER THE CODE REQUIRES AN ELEVATOR TO BE |
| | INSTALLED IN SUCH BUILDING, STRUCTURE OR FACILITY, |
| | EXCEPT: (1) ELEVATOR PITS, ELEVATOR PENTHOUSES, |
| | MECHANICAL ROOMS, PIPING OR EQUIPMENT CATWALKS, AND |
| | AUTOMOBILE LUBRICATION AND MAINTENANCE PITS AND |
| | PLATFORMS; (2) UNOCCUPIABLE SPACES, SUCH AS ROOMS, |
| | ENCLOSED SPACES, AND STORAGE SPACES THAT ARE NOT |
| | DESIGNED FOR HUMAN OCCUPANCY, FOR PUBLIC |
| | ACCOMMODATIONS, OR FOR WORK AREAS; AND (3) OCCUPIABLE |
| | SPACES AND ROOMS THAT ARE NOT OPEN TO THE PUBLIC AND |
| | THAT HOUSE NO MORE THAN FIVE PERSONS INCLUDING, BUT NOT |
| | LIMITED TO, EQUIPMENT CONTROL ROOMS AND PROJECTION |
| | BOOTHS. HOWEVER AS PROVIDED IN SECTION 553.509, FLORIDA |
| | STATUTES, BUILDINGS, STRUCTURES, AND FACILITIES MUST, |
| | AT A MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE |
| | ADAAG. THEREFORE, FACILITIES SUBJECT TO THE ADAAG MAY |
| | BE REQUIRED TO PROVIDE VERTICAL ACCESS TO AREAS |
| | OTHERWISE EXEMPT UNDER SECTION 11-4.1.3(5) OF THIS |
| | CODE. |
| | AN ACCESSIBLE SITE SHALL MEET THE FOLLOWING MINIMUM |
| | REQUIREMENTS: |
| | (1) AT LEAST ONE ACCESSIBLE ROUTE COMPLYING WITH |
| | SECTION 11-4.3 SHALL BE PROVIDED WITHIN THE BOUNDARY OF |
| | THE SITE FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE |
| | PARKING SPACES, PASSENGER LOADING ZONES IF PROVIDED, |
| | AND PUBLIC STREETS OR SIDEWALKS, TO AN ACCESSIBLE |
| | BUILDING ENTRANCE. |
| | (2) AT LEAST ONE ACCESSIBLE ROUTE COMPLYING WITH |
| | SECTION 11-4.3 SHALL CONNECT ACCESSIBLE BUILDINGS, |
| | ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND |
| | ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. |
| | |
| | 3) PLEASE SEE ZONING COMMENT AS TO THE AMOUNT OF OVER |
| | ALL PARKING STALLS. |
| | |
| | 4) PLEASE ALSO SEE ZONINGS COMMENT ABOUT NEW CANOPY, |
| | ALTHOUGH NOT PART OF THIS PERMIT IT IS A LOADING ZONE |
| | REQUIRING A MINIMUM CLEARENCE : |
| | 11-4.6.5 VERTICAL CLEARANCE. PROVIDE MINIMUM VERTICAL |
| | CLEARANCE OF 114 INCHES (2895 MM) AT ACCESSIBLE |
| | PASSENGER LOADING ZONES AND ALONG AT LEAST ONE VEHICLE |
| | ACCESS ROUTE TO SUCH AREAS FROM SITE ENTRANCE(S) AND |
| | EXIT(S). AT PARKING SPACES COMPLYING WITH SECTION |
| | 11-4.1.2(5)(B), PROVIDE MINIMUM VERTICAL CLEARANCE OF |
| | 98 INCHES (2490 MM) AT THE PARKING SPACE AND ALONG AT |
| | LEAST ONE VEHICLE ACCESS ROUTE TO SUCH SPACES FROM SITE |
| | ENTRANCE(S) AND EXIT(S). |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISC |