Plan Review Notes
Plan Review Notes For Permit 08080540
Permit Number 08080540
Review Stop B
Sequence Number 1
Notes
Date Text
2008-09-02 12:02:50****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. SEE PAGE 4 OF THE PANEL PRODUCT APPROVAL AND
 OPENINGS 17-19. C1 INTO HOLLOW CONCRETE BLOCK REQUIRES
 7" ANCHOR SPACING; C2 NOT PERMITTED.
  
 2. ACCORDION SHUTTER CONNECTION MOUNTING TYPE SHOULD
 CORRELATE WITH THE ANCHOR CHARTS; FOR INSTANCE, WALL
 MOUNT 1, FLOOR MOUNT 6, ETC. NOTE THAT SOME CONNECTION
 TYPES ARE PERMITTED IN CONCRETE ONLY.
  