| 2008-09-08 14:20:43 | BUILDING PLAN REVIEW |
| | PERMIT: 08080507 |
| | ADD: 2161 PBL BLVD |
| | CONT: RE-ANDERSON CONSTRUCTION INC. |
| | TEL: (561)776-7389 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | |
| | 9-8-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS. |
| | |
| | 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN |
| | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF |
| | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF |
| | THIS CODE. |
| | |
| | 5) PROVIDE AN EXISTING AND A PROPOSED FLOOR PLAN |
| | SHOWING ALL CHANGES TO THE EXISTING LAYOUT OF THE |
| | SPACE. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED. FBC 106.1.1 |
| | |
| | 6) THE DRAWINGS NEED TO INDICATE THE TYPE OF BUILDING |
| | PER FBC CHAPTER 6 AND THE USE AND OCCUPANCY PER FBC |
| | CHAPTER 3. STATE THE OCCUPANT LOAD OF THE SPACE PER FBC |
| | TABLE 1004.1.2. NOW THE SPACE HAS BEEN ALTERED PROVIDE |
| | A LIFE SAFETY PLAN SHOWING THE MEANS OF EGRESS WHICH |
| | SHALL INCLUDE EXIT ACCESS, EXITS AND EXIT DISCHARGE: |
| | ALSO, IF THE BUILDING IS EQUIPPED WITH AND AUTOMATIC |
| | SPRINKLER SYSTEM SHOW THE LOCATION OF THE SPRINKLER IN |
| | RELATION TO THE NEW WALLS. THIS CAN BE SHOWN ON THE |
| | REFLECTED CEILING PLANS. FBC 106.3.5.1.1(5) (6)* |
| | |
| | 7) SHEET A-3 A PORTION OF THE RECEPTIONIST DESK SHALL |
| | BE A MAXIMUM HEIGHT OF 36 INCHES AND A MINIMUM WIDTH OF |
| | 36 INCHES; DETAIL #6 ON SHEET A-3 DO NOT MEET THIS |
| | REQUIREMENT. NOTE: THIS SPACE SHALL BE PROVIDED TO THE |
| | CUSTOMERS COMING IN FOR SERVICE. SHOW COMPLIANCE. |
| | |
| | 8) SHEET A-2 IS MISSING THE DETAIL INFORMATION FOR WALL |
| | TYPES [A] AND [E]. THIS SHEET HAS TWO DETAIL WALLS |
| | SHOWING AS A TYPE [B]. THE WALL LEGEND ON SHEET A-2 |
| | SHOWS THE NEW WALL TYPES A/B/C AND E CLARIFY. |
| | ADDITIONAL INFORMATION IS REQUIRED SHOWING THE CORRECT |
| | TYPES OF WALLS. 106.1.2* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |