| 2008-08-21 17:30:28 | RESIDENTIAL (R3) ADDITION AND RENOVATION BUILDING |
| | REVIEW CHECKLIST. |
| | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. |
| | |
| | 1- BRING PLANS TO PALM BEACH COUNTYTO VERIFY IF |
| | IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY |
| | OF PAID RECEIPT IF FEES ARE DUE. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | 13-101.2.2 FBC 2004. |
| | NOTE: PLEASE MAKE SURE CORRECT REVISED FORM IS USED |
| | AND IS FILLED COMPLETELY TO AVOID UNNECESSARY DELAYS. |
| | |
| | 3-PLANS TO SPECIFY SAFETY GLASS FOR WINDOWS BY |
| | BREAKFAST AREA AND BY SHOWER AREA AS REQUIRED BY SEC. |
| | R308.4 OF 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A)FIXED ARCHED WINDOW. SEE PLANS. |
| | |
| | B) WINDOW MULLION. SEEPLANS. |
| | |
| | C) SINGLE HUNG WINDOWS. NEED TO PROVIDE PRODUCT |
| | APPROVAL THAT MEETS ALL THE DESIGN PRESSURES CALCULATED |
| | FOR WINDOW W2. |
| | |
| | D) FLAT ROOF: |
| | (1) SPECIFYSPECIFIC APPROVED ASSEMBLY TO BE USED. |
| | |
| | (2) SPECIFY SPECIFIC BASE SHEET FASTENING OPTION TO |
| | BE USED. |
| | (3) PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING |
| | AT PERIMETER &CORNER AREAS AS REQ'D BY GENERAL |
| | LIMITATION #7 ONNOA 07-0111.03. |
| | |
| | 5- SHEET SP-1:DESIGN CRITERIA CALLS FOR EXPOSURE "C", |
| | WHILE STRUCTURAL SHEETSS-1 AND S-3 CALL FOR EXPOSURE |
| | "B". REVISE AS REQUIRED TO MATCH. |
| | |
| | 6- SHEET A-1: |
| | A) CRAWL SPACE VENTILATION TO COMPLY WITH THE |
| | MINIMUM SIZE,LOCATION AND ACCESS REQUIREMENTS OF SEC. |
| | R408 OF 2004 FLORIDA RESIDENTIAL CODE. REVISE AS |
| | REQUIRED. |
| | NOTE:REVISE EXTERIOR ELEVATIONS TO REFLECT LOCATION |
| | OF VENTS AS WELL. |
| | |
| | B) REVISE UNDER FLOOR VENTILATION NOTES:REFERENCE |
| | CODE SECTIONSFROM THE FLORIDA RESIDENTIAL CODE, NOT |
| | FROM THEFBC. |
| | |
| | C) REVISE RISER TREAD RATIO TO COMPLY WITH SEC. |
| | R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. |
| | NOTE: REVISE THIS INFORMATION ON STRUCTURAL DRAWINGS |
| | ALSO. |
| | |
| | 7- SHEET A-2: |
| | A) EMERGENCY ROOF DRAIN SCUPPERS TO COMPLY WITH |
| | SEC. R903.4.1 OF 2004 FLORIDA RESIDENTIAL CODE. SPECIFY |
| | HEIGHT FROM THE FINISHED ROOF COVERING. |
| | |
| | B) REVISE ROOF DRAINAGE NOTES:REFERENCE CODE |
| | SECTIONSFROM THE 2004 FLORIDA RESIDENTIAL CODE, NOT |
| | THE 2004 FBC. |
| | |
| | 8- SHEET A-4: |
| | A) TYPICAL WALL SECTION: |
| | (1) CLARIFY WHYVENTING IS NOT REQUIRED. SPECIFY |
| | WHICH CODE SECTIONS STATES THAT NO VENTILATION IS |
| | REQUIRED ON ROOF.ACCORDING TO SEC. R806 OF 2004 |
| | FLORIDA RESIDENTIAL CODECROSS VENTILATION IS |
| | REQUIRED. SPECIFYIN PLANS/ELEVATIONS SIZE AND |
| | LOCATION OF CROSS VENTILATION. |
| | |
| | (2) SPECIFYHOW PROVIDING PROTECTION TO THE FLOOR |
| | JOIST AS REQUIRED BY SEC. R319 .1 OF 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | (3) REVISE SIZE OF FLOOR JOIST TO MATCH SIZE SHOWN |
| | ON STRUCTURAL PLANS. |
| | |
| | 9- SHEET S-2:REVISE NOTES ON TYPICAL WIND PRESSURE |
| | BOX SHOWN ON THE FLOOR PLAN D.DISTANCE "A" TO BE |
| | 4'-0" MIN. AS REQUIRED BY NOTE A ON FIGURE R301.2(8) OF |
| | 2004 FLORIDA RESIDENTIAL CODE. |
| | ***NOTE:REVISE SAME INFORMATION ON SHEET S-3. |
| | |
| | 10- OWES $5.02 FOR RADON FEES FOR NEW ADDITION. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |