| Date |
Text |
| 2008-08-22 16:14:34 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 08080113 |
| | ADD: 1558 PBL BLVD SUITE #5 |
| | CONT: HALLMARK & SONS INC. |
| | TEL: (561)644-3498 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 8-22-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) SHEET A1, THE ACCESSIBLE SINK NEXT TO THE BATH ROOM |
| | NEEDS TO BE IN COMPLIANCE WITH SECTION 11-4.24. EVEN |
| | THOUGH SHEET A4 SHOWS SOME DETAILS, OTHER IMPORTANT |
| | ONES ARE MISSING FROM SHEET A1. SHOW THE CLEAR FLOOR |
| | SPACE WHICH SHALL BE AT LEAST 30 INCHES BY 48 INCHES. |
| | PLEASE NOTE: DOORS SHALL NOT SWING INTO THE CLEAR FLOOR |
| | SPACE REQUIRED FOR ANY FIXTURE FBC 11- 4.22.2 (NOTE |
| | BATH ROOM DOOR NEXT TO SINK). |
| | |
| | 4) THE WALL LEGEND ON SHEET A1 SHOWS TWO TYPES OF WALL, |
| | HOWEVER, SHEET A4 SHOWS FOUR DIFFERENT TYPES OF WALLS |
| | WHICH ARE NOT CLEARLY INDICATED ON THE FLOOR PLANS. |
| | PLEASE IDENTIFY EACH WALL ON THE FLOOR PLANS WITH A |
| | NUMBER OR LETTER SO WE CAN KNOW WHICH WALL WILL BE |
| | CONSTRUCTED. CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED. FBC 106.1.1 |
| | |
| | 5) SUBMIT EXISTING AND PROPOSED FLOOR PLANS TO SHOW ALL |
| | WALLS TO BE DEMOED AND WHICH ONES ARE NEW. THE |
| | ADDITIONAL INFORMATION IS REQUIRED SO WE CAN HAVE AN |
| | UNDERSTANDING AS TO WHERE ALL THE CHANGES ARE MADE. FBC |
| | 106.1.2* |
| | |
| | 6) PROVIDE ELEVATION DRAWINGS TO SHOW FRAMED OPENING |
| | FOR THE GLASS WINDOWS ON SHEET A1. THE DRAWING SHALL |
| | ALSO SHOW HOW HIGH THE BOTTOM OF THE GLASS IS ABOVE THE |
| | FINISH FLOOR. ADDITIONAL INFORMATION REQUIRED FBC |
| | 106.1.2* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |