2008-08-22 08:02:42BUILDING PLAN REVIEW
 PERMIT: 08080065
 ADD: 529 S. FLAGLER DR. #264
 CONT: DESIGN CONTRACTING INC,
 TEL: (561)514-2004
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE. THE LEVEL OF ALTERATION SHALL BE STATED ON
 THE PLANS.
  
 5) PROVIDE AN EXISTING AND A PROPOSED FLOOR PLAN TO
 SHOW EXACTLY WHERE ALL CHANGES WILL OCCUR THROUGH OUT
 THE SPACE. IT APPEARS THAT THERE WILL BE NEW SOFFITS
 CONSTRUCTED IN VARIOUS ROOMS; PLEASE INDICATE THE
 FASTENERS ATTACHMENT AND SPACING FOR THE TOP METAL
 TRACK. DOES THE MARBLE FLOOR EXIST OR A NEW ONE WILL BE
 INSTALLED? IF THIS IS A NEW FLOOR SYSTEM, PLEASE TAKE
 NOTE THAT FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING
 UNITS OR BETWEEN A SWELLING UNIT AND PUBLIC OR SERVICE
 AREA WITH IN THE STRUCTURE SHALL HAVE AND IMPACT
 INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45
 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E
 492. FBC 1207.3. PROVIDE THE MANUFACTURE SPECIFICATIONS
 FOR THE CORK.
  
 6) INDICATE ON THE PLANS THE USE AND OCCUPANCY OF THE
 BUILDING AND THE TYPE OF BUILDING PER CHAPTER 3 AND 6
 RESPECTIVELY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER