| 2008-09-25 08:13:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. SEE SHEET 11 OF THE PRODUCT APPROVAL. A .83 FACTOR | | | IS REQUIRED FOR A 3" EDGE DISTANCE; THEREFORE THE 8" | | | ANCHOR SPACING DOES NOT MEET THE REQUIREMENTS FOR THE | | | DESIGN PRESSURES SPECIFIED. PLEASE REVISE THE | | | INSTALLATION SCHEDULE. | | | | | | |
|