| 2008-08-13 16:44:06 | RESIDENTIAL (R3)SHUTTERS, BUILDING REVIEW CHECKLIST. |
| | |
| | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. |
| | |
| | 1- ACCORDION SHUTTERS NOA 06-0503.03FILE IS CLOSED |
| | BY MIAMI-DADE COUNTY PRODUCT APPROVAL DIVISION. SEE |
| | ATTACHED COPYFROM DADE COUNTY WEB-SITE.NEED TO |
| | PROVIDE CURRENTPRODUCT APPROVAL WHOSE FILE IS NOT |
| | CLOSED. |
| | |
| | 2-A) IF THE EDGE DISTANCE ON INSTALLATION SCHEDULE |
| | COLUMN #8IS31/2",THEN THE SHUTTER SPAN ON |
| | COLUMN #6NEEDS TO BE CHANGED TO REFLECT THE EDGE |
| | DISTANCE ACCORDING TO THE SIZE OPENING.SHUTTER SPAN |
| | SPECIFIED IN THE INSTALLATION SCHEDULE IS ONLY 2 INCHES |
| | LONGER THAN THE OPENING HEIGHT.THIS NUMBER DOESN'T |
| | WORK WITH 3 1/2"EDGE DISTANCE.NOTE: EDGE DISTANCE |
| | DOESN'T TAKE INTO CONSIDERATION THE STUCCO FINISH OR |
| | ANY OTHER WALL FINISH. SEE GENERAL NOTE#7 ON SHEET 1 |
| | OF 6 OF DRAWING 06-010 SUBMITTED. |
| | |
| | B) CLARIFY WHY SHUTTER SPAN ON OPENING #2 IS THE |
| | SAME SIZE AS THE OPENING SIZE. |
| | |
| | 3- REVISE LENGTH OF TAPCON SPECIFIEDTO MEET THE |
| | MINIMUM EMBEDMENT REQUIREMENTS OFGENERAL NOTE #7.1 |
| | 3/4" TAPCONS SPECIFIED ON THE INSTALLATION SCHEDULE |
| | DON'T PROVIDE THE REQUIRED EMBEDMENT. REVISE AS |
| | REQUIRED. STUCCO OR ANY OTHER WALL FINISH SHALL NOT BE |
| | CONSIDERED FOR THE MINIMUM EMBEDMENT REQUIRED. |
| | |
| | 4-INSTALLATION SCHEDULE CALLS FOR SUBSTRATE TO BE |
| | POURED CONCRETE AT TOP AND BOTTOM OF OPENING.PROVIDE |
| | PROOF/TESTING THAT THE BOTTOM OF OPENING IS ALSO |
| | 3000PSI POURED CONCRETE.OTHERWISE USE THE ANCHOR |
| | SPACING FOR MASONRY INSTALLATION ON SHEET 5 OF 6 OF |
| | DRAWING 06-010 SUBMITTED. |
| | NOTE: TYPICALLY TOP OF OPENING IS CONCRETE BECAUSE IS A |
| | PRECAST LINTEL OR POURED TIE BEAM.AND BOTTOM OF |
| | OPENING ISUSUALLY CONCRETEBLOCK CELLS FILLED WITH |
| | CONCRETE. THAT'S WHY PROOF OF EXISTING SUBSTRATE IS |
| | REQUIRED TO PROPERLY USE CORRESPONDING ANCHOR SPACING. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |