| 2008-07-28 09:35:18 | GAS PLAN REVIEW: |
| | DENIED: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | GAS PLAN REVIEW TO MEET THE CITY OF WEST PALM BEACH GAS |
| | PERMIT APPLICATION REQUIREMENTS FOR CODE COMPLIANCE. |
| | |
| | 1. SUBMIT AN ISOMETRIC DRAWING THAT |
| | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| | AND CORRESPONDING LENGTHS. PER FBC-2004 |
| | FUEL GAS CODE SECTION 401.1 SCOPE. |
| | *NOTE: THE SUBMITTED ISOMETRICDOES NOT SHOW |
| | CORRESPONDING LENGTHS TO ALL CUT SECTIONS OF PIPE. |
| | PLEASE REFERENCE THE YELLOW HIGH LIGHTED CUT SECTIONS |
| | THAT DO NOT INDICATE CORRESPONDING LENGTHS. |
| | |
| | 2. SHOW TYPE OF PIPING MATERIAL BEING |
| | INSTALLED, ALL PIPE SIZES, (AND THE EDH |
| | NUMBER OF CORRUGATED STAINLESS STEEL |
| | TUBING FOR EACH PIPE SIZE BEING USED. |
| | PER FBC-2004 FUEL GAS SECTION 401.1 SCOPE. |
| | *NOTE: SOME PIPING MATERIAL AND PIPE SIZES ARE NOT |
| | CLEARLY BEING INDICATED. CLEARLY SIZE THE PIPING |
| | MANIFOLD AT THE GAS METER, RISER TO THE BBQ, RISER TO |
| | THE POOL HEATER MUST BE 1 INCH (1") AND CAN BE REDUCED |
| | AT THE HEATER. PIPING FROM THE METER OUTLET TO THE POOL |
| | HEATER TEE MUST BE 1-1/4 INCH (1-1/4"). |
| | |
| | 3. SHOW THE DISTANCE FROM THE POINT OF |
| | DELIVERY, (METER), TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| | FBC-2004 FUEL GAS CODE APPENDIX A - USE |
| | OF CAPACITY TABLES A.3.1(4). |
| | *NOTE: THE LONGEST LENGTH OF 13'-6" IS INCORRECT ON |
| | THE DRAWING. UNTIL COMMENT #1 IS COMPLETELY ADDRESSED |
| | AND THE RESUBMITTED PLANS ARE CORRELATED TO REFLECT THE |
| | CORRESPONDING LENGTHS TO ALL CUT SECTIONS OF PIPE THE |
| | GAS PLANS WILL NOT PASS PLAN REVIEW. TABLES BEING USED |
| | FOR PLAN REVIEW ARE 401.4(2) AND 401.4(20), PLEASE |
| | REFERENCE THESE TABLES ATTACHED TO THE COMMENTS TO HELP |
| | IN THE RESUBMITTAL. |
| | |
| | 4. PLEASE CLEARLY INDICATE ON THE RESUBMITTED DRAWINGS |
| | IF THE TANKLESS WATER HEATER IS AN INTERIOR OR AN |
| | EXTERIOR MODEL. PER FBC-2004 FUEL GAS SECTION 401.1 |
| | SCOPE. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |