| 2008-08-18 09:05:07 | BUILDING PLAN REVIEW |
| | PERMIT: 08070709 |
| | ADD: 480 HIBISCUS ST. #104 |
| | CONT: THE TOWER GROUP |
| | TEL: (954)476-3200 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 8-15-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) INDICATE THE OCCUPANT LOAD OF THE SPACE PER TABLE |
| | 1004.1.2. THE OCCUPANT LOAD OF THE MEZZANINE SHALL ALSO |
| | BE INDICATED; STATE THE USE OF THE MEZZANINE AND THE |
| | LIVE LOAD OF THE FLOOR PER FBC 1603.3 AND 1603.4. |
| | PLEASE SEE TABLE 1607.1 FOR ADDITIONAL LOAD INFORMATION |
| | FOR THE UNIFORM AND CONCENTRATED LOAD. |
| | |
| | 4) DUE TO THE FACT THAT THE BASE BUILDING DOES NOT HAVE |
| | A CERTIFICATE OF OCCUPANCY, ALL PROJECTS FOR TENANT |
| | BUILD OUT PERMITTED BEFORE THE CO OF THE BASE BUILDING |
| | SHALL HAVE A REVIEW STAMP AND THE SIGNATURE FROM THE |
| | DESIGNER OF RECORD OF THE BASE BUILDING ON EACH SHEET. |
| | THE BASE BUILDING DESIGNERS IS RESPONSIBLE FOR THE |
| | BUILDING UNTIL IT IS CO. FLORIDA STATUTES 471 AND 481. |
| | |
| | 5) THE DRAWING INDICATES ALTERATION LEVEL 3 WHICH MEANS |
| | THE WORK IN THE AREA EXCEEDS 50 PERCENT OF THE |
| | AGGREGATE AREA OF THE BUILDING AND IS MADE WITHIN A |
| | TWELVE MONTH PERIOD; BECAUSE THE SPACE HAS NEVER BEEN |
| | OCCUPIED, THIS WILL BE CONSIDERED AS NEW CONSTRUCTION |
| | SO, NO ALTERATION LEVEL IS REQUIRED. |
| | |
| | 7) FBC 1013.3 (EXCEPTION #5) SHOW THE COMMON PATH OF |
| | EGRESS TRAVEL WHICH SHALL BE 100 FEET IN BUILDINGS WITH |
| | AN AUTOMATIC SPRINKLER SYSTEM INSTALLED THROUGHOUT. |
| | |
| | 8) FBC 1009.5 ALL STAIRS SHALL BE BUILT OF MATERIALS |
| | CONSISTENT WITH THE CONSTRUCTION TYPE OF THE BUILDING |
| | WHICH IS TYPE IB. ONLY THE HANDRAILS CAN BE CONSTRUCTED |
| | OF WOOD. |
| | |
| | 9) DUE TO THE FACT THAT THIS FACILITY USE IS |
| | MERCANTILE,WHICH IS OPEN TO THE PUBLIC THE REQUIREMENTS |
| | OF THIS SECTION SHALL BE MET.11-4.1.2 NEW CONSTRUCTION: |
| | NOTHING IN THIS CODE SHALL BE CONSTRUED TO RELIEVE THE |
| | OWNER OF ANY BUILDING, STRUCTURE OR FACILITY FROM THE |
| | DUTY TO PROVIDE VERTICAL ACCESSIBILITY TO ALL LEVELS |
| | ABOVE AND BELOW THE OCCUPIABLE GRADE LEVEL, REGARDLESS |
| | OF WHETHER THE CODE REQUIRES AN ELEVATOR TO BE |
| | INSTALLED IN SUCH BUILDING, STRUCTURE OR FACILITY, |
| | EXCEPT: (1) ELEVATOR PITS, ELEVATOR PENTHOUSES, |
| | MECHANICAL ROOMS, PIPING OR EQUIPMENT CATWALKS, AND |
| | AUTOMOBILE LUBRICATION AND MAINTENANCE PITS AND |
| | PLATFORMS; (2) UNOCCUPIABLE SPACES, SUCH AS ROOMS, |
| | ENCLOSED SPACES, AND STORAGE SPACES THAT ARE NOT |
| | DESIGNED FOR HUMAN OCCUPANCY, FOR PUBLIC |
| | ACCOMMODATIONS, OR FOR WORK AREAS; AND (3) OCCUPIABLE |
| | SPACES AND ROOMS THAT ARE NOT OPEN TO THE PUBLIC AND |
| | THAT HOUSE NO MORE THAN FIVE PERSONS INCLUDING, BUT NOT |
| | LIMITED TO, EQUIPMENT CONTROL ROOMS AND PROJECTION |
| | BOOTHS. HOWEVER AS PROVIDED IN SECTION 553.509, FLORIDA |
| | STATUTES, BUILDINGS, STRUCTURES, AND FACILITIES MUST, |
| | AT A MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE |
| | ADAAG. THEREFORE, FACILITIES SUBJECT TO THE ADAAG MAY |
| | BE REQUIRED TO PROVIDE VERTICAL ACCESS TO AREAS |
| | OTHERWISE EXEMPT UNDER SECTION 11-4.1.3 (5) OF THIS |
| | CODE. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |