| 2008-11-18 12:59:29 | BUILDING PLAN REVIEW |
| | PERMIT: 08070706 |
| | ADD: 480 HIBISCUS ST. #106 |
| | CONT: THE TOWER GROUP |
| | TEL: (954)476-3200 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 11-18-08 |
| | REVIEW: 2ND |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | **IS THIS A MERCANTILE OCCUPANCY ONLY; IF BUSINESS |
| | OFFICES ARE LOCATED IN THIS SPACE THEN, THE OCCUPANCY |
| | MAY CHANGE. CLARIFY. CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICENT CLARITY. 106.1.1** |
| | 3) INDICATE THE OCCUPANT LOAD OF THE SPACE PER TABLE |
| | 1004.1.2. THE OCCUPANT LOAD OF THE MEZZANINE SHALL ALSO |
| | BE INDICATED; STATE THE USE OF THE MEZZANINE AND THE |
| | LIVE LOAD OF THE FLOOR PER FBC 1603.3 AND 1603.4. |
| | PLEASE SEE TABLE 1607.1 FOR ADDITIONAL LOAD INFORMATION |
| | FOR THE UNIFORM AND CONCENTRATED LOAD. |
| | |
| | **NO RESPONSE NOT ADDRESSED** |
| | 4) FBC 505.1 MEZZANINES ARE REQUIRED TO HAVE A CEILING |
| | HEIGHT OF NOT LESS THAN 7 FEET AND THE CEILING BELOW |
| | MUST ALSO BE AT LEAST 7 FEET. PROVIDE A FRONT ELEVATION |
| | OF THE MEZZANINE SHOWING THESE REQUIREMENTS. |
| | |
| | **NO RESPONSE NOT ADDRESSED** |
| | 5) DUE TO THE FACT THAT THE BASE BUILDING DOES NOT HAVE |
| | A CERTIFICATE OF OCCUPANCY, ALL PROJECTS FOR TENANT |
| | BUILD OUT PERMITTED BEFORE THE CO OF THE BASE BUILDING |
| | SHALL HAVE A REVIEW STAMP AND THE SIGNATURE FROM THE |
| | DESIGNER OF RECORD OF THE BASE BUILDING ON EACH SHEET. |
| | THE BASE BUILDING DESIGNERS IS RESPONSIBLE FOR THE |
| | BUILDING UNTIL IT IS CO. FLORIDA STATUTES 471 AND 481. |
| | |
| | **AFTER FURTHER INVESTIGATION, I FOUND OUT THIS IS A |
| | NEW BUILDING THAT HAS NOT BEING OCCUPIED. THEREFORE, NO |
| | ALTERATION LEVEL IS REQUIRED. THIS IS ALL NEW |
| | CONSTRUCTION** |
| | 6) THE DRAWING INDICATES ALTERATION LEVEL 3 WHICH MEANS |
| | THE WORK IN THE AREA EXCEEDS 50 PERCENT OF THE |
| | AGGREGATE AREA OF THE BUILDING AND IS MADE WITHIN A |
| | TWELVE MONTH PERIOD; FBC(EXISTING) 305.1. IS THIS THE |
| | CASE FOR THIS PROJECT? IF NOT PLEASE SEE SECTION 304 OF |
| | THE FBC (EXISTING) ALTERATION LEVEL 2. |
| | |
| | NOTE: PLEASE INDICATE THE TYPE AND MAKE OF THE |
| | MECHANICAL ROOM DOOR. IS THE DOOR A NON-COMBUSTIBLE |
| | DOOR? ADDITIONAL INFORMATION IS REQUIRED 106.1.2. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |