| 2008-08-07 15:05:14 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS A TWO STORY RESIDENCE LOCATED IN | | | EXPOSURE CATEGORY C WITH THE OPENINGS IN WALL ZONE 5 . | | | THE COMPONENT & CLADDING PRESSURES SPECIFIED ON A-1 ARE | | | TOO LOW. THE PRESSURES HAVE NOT BEEN ADJUSTED FOR | | | HEIGHT AND EXPOSURE AS REQUIRED BY NOTES FOR FBC TABLE | | | R301.2(2). PLEASE REVISE. | | | | | | 2) THE PRODUCT APPROVALS FOR THE CASEMENT WINDOWS ARE | | | REQUIRED TO BE APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD. FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. | | | THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 3) THE JOB LOCATION IN THE TITLE BLOCK OF THE DRAWINGS | | | INCORRECTLY LISTS THE TOWN OF PALM BEACH. THE JOB IS | | | LOCATED IN THE CITY OF WEST PALM BEACH. PLEASE | | | CORRECT. | | | | | | 4) THE ENGINEER IS REQUIRED TO LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER ON EACH SHEET OF PLANS. FAC | | | 61G15-23.002 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|