| Plan Review Notes For Permit 08070481 |
| Permit Number |
08070481 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2008-09-08 10:07:56 | 2004 FBC W/2007 REVISIONS | | | REVISE SCOPE OF WORK TO ADD 1 SQUARE OF GAF MODIFIED ON | | | FLAT ROOF | | | | | | DENIED BY BUILDING | | | | | | 1) SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED | | | IN THE NOA WILL BE INSTALLED. | | | | | | 2) SPECIFY WHICH FASTENING OPTION AND MAXIMUM DESIGN | | | PRESSURE WILL BE USED. | | | | | | 3) SUBMIT 2 COPIES OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING FROM AN ENGINEER, | | | ARCHITECT OR REGISTERED ROOF CONSULTANT, AS REQUIRED BY | | | GENERAL LIMITATION NUMBER 7 ON PAGE 30 OF THE NOA. | | | | | | 4) THE VALUE OF THE WORK HAS BEEN INCREASED TO INCLUDE | | | THE ADDITIONAL SCOPE OF WORK. ADDITIONAL FEES OF $ | | | 10.71 ARE DUE. FBC 108.1* CITY AMENDMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|