Plan Review Notes
Plan Review Notes For Permit 08070305
Permit Number 08070305
Review Stop Z
Sequence Number 1
Notes
Date Text
2008-07-23 12:11:30FAILED
  
 1) THE CITYPLACE STAMP IS NOT ON THE RENDERINGS OR
 SHEET B-A4.07.
  
 2) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS
 MUST PROVIDE A MINIMUM OF EIGHT (8) FEET OF CLEARANCE
 BETWEEN THE FLOOR AND THE LOWEST POINT OF THE AWNING.
 THE AWNING SHOWN ON SHEET 1 DOES NOT INCLUDE A HEIGHT,
 THE AWNING ON SHEET 2 IS LISTED AS 7' 6", AND THE
 AWNING SHOWN ON SHEET 3, WHILE LISTED AS MINIMUM OF 7'
 6" IS ON THE SECOND STORY SO IT NEEDS TO GIVE TRUE
 HEIGHT.
  
 3) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS
 ON THE SECOND FLOOR SHALL PROJECT THREE (3) FEET FROM
 THE BUILDING FACADE.THE AWNING SHOWN ON SHEET 1
 PROJECTS 8' 3" FROM THE BUILDING FACADE, THE AWNING ON
 SHEET 2 PROJECTS 10' FROM THE BUILDING FACADE, AND THE
 AWNING SHOWN ON SHEET 3 PROJECTS 3' FROM NOT THE
 BUILDING FACADE, BUT FROM THE OUTER EDGE OF THE
 ARCADE.
  
 4) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT BOTH
 SIDES OF A SHED AWNING MUST BE OPEN.THE SHED AWNING
 ON SHEET 3 ARE NOT OPEN.
  
 5) THE CITYPLACE MASTER SIGN PLAN DOES NOT ALLOW
 VALANCES ON SECOND STORY AWNINGS.ALL AWNINGS SHOWN
 HAVE VALANCES.
  
 6) THE CITYPLACE MASTER SIGN PLAN ALLOWS VARIANCES FROM
 THE PROVISIONS OF 2, 3, 4 & 5 ABOVE.PROVIDE A
 NOTARIZED LETTER FROM CITYPLACE THAT THEY HAVE GRANTED
 THE SPECIFIC VARIANCES NEEDED TO CONSTRUCT THE PROPOSED
 AWNINGS OR REVISE AWNINGS TO ADHERE TO THE CITYPLACE
 MASTER SIGN PLAN REQUIREMENTS.
  
 7) THE TAVERNA OPA COPY SHOWN ON THE RENDERINGS
 REQUIRES APPROVAL THROUGH A SIGN PERMIT.NOTE THAT THE
 SQUARE FOOTAGE OF SIGNAGE ON THE WESTERN ELEVATION
 VALANCES (PROVIDED THE VARIANCE TO 5 ABOVE IS GRANTED
 IN WRITING BY CITYPLACE) IS REQUIRED TO BE INCLUDED
 WITH THE AMOUNT OF SIGNAGE SQUARE FOOTAGE PROPOSED BY
 THE TAVERNA OPA SIGN PERMIT NUMBER 08070155.REMEMBER
 1 SQUARE FOOT OF SIGNAGE IS ALLOWED FOR 1 LINEAR FOOT
 OF FRONTAGE, UNLESS CITYPLACE GRANTS A VARIANCE IN
 WRITING.
  
 8) THE POSTS TO CONTACT THE AWNING TO THE "RED STEEL
 BEAM" ARE SHOWN ON SHEET 3 AS 8' IN LENGTH.A REVIEW
 OF THE AWNING LOCATIONS ON THE RENDERINGS SEEMS TO
 CONTRADICT THAT AN 8' TALL POST WILL FIT UNDER AN EVE
 ON THE SLOPED ARCADE ROOF THAT APPEARS TO BE
 APPROXIMATELY 1' IN HEIGHT.
  
 9) PROVIDE DIMENSIONS ON THE RENDERINGS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.