| Date |
Text |
| 2008-10-03 12:46:17 | |
| | ** DENIED ** |
| | |
| | |
| | ** PLANS ARE IN GOOD SHAPE. THE FOLLOWING ITEMS COULD |
| | HAVE BEEN REDLINED OR *PROVISO* ITEMS HOWEVER PLANS ARE |
| | COMING BACK FOR COMMENTS FROM OTHER TRADES. PLEASE |
| | ADDRESS AT THIS TIME. |
| | |
| | 1) NOTE: PLEASE SEE PREVIOUS REVIEW GAVE NOTES TO FBC |
| | 13-415.1.ABC.1.4 FOR EXTERIOR LIGHTING CONTROLS. THE |
| | DETAIL ADDED TO THE SHEET E-6 DOES PROVIDE THE |
| | ASTRONOMICAL TIME CLOCK AS REQUIRED HOWEVER IF NOT |
| | USING A PHOTO-SENSOR AS THE OVER RIDE THE CODE REQUIRES |
| | A MINIMUM OF 10HRS FOR BATTERY BACK UP OF PROGRAMMING. |
| | PLEASE MAKE NOTE OF THE 10HR BACK UP. |
| | THIS WAS REDLINED ON PLANS AS THIS IS A MINOR ITEM. |
| | |
| | 2) NOTE: PLEASE PROVIDE INFORMATION FOR LIGHTING IN |
| | SEPARATE SPACES. THE PLANS FOR BOTH NOTE #6 AND NOTE #7 |
| | GIVE NOTES TO SEE DETAIL ON SHEET E-7. THE PLANS STILL |
| | ACTUALLY SHOW THE OCCUPANCY SENSOR DEVICE FOR AREAS |
| | NOTED AS NOTE #6 HOWEVER NOT THE DEVICE FOR NOTE #7. IF |
| | THESE ARE GOING TO BE WALL MOUNTED PLEASE SHOW |
| | LOCATIONS SO COVERAGE MAY BE VERIFIED. FOR AN EXAMPLE |
| | OF THIS IS THE FUTURE BUILD OUT SPACES. IF A WALL |
| | MOUNTED OCCUPANCY SENSOR IS GOING TO BE USED IN |
| | CONJUNCTION WITH THE SINGLE POLE SWITCH COVERAGE NEEDS |
| | TO BE SHOWN AS AREAS ARE NOT SQUARE. PLEASE CALL TO GO |
| | OVER |
| | |
| | |
| | |
| | |
| | |
| | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT |
| | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO |
| | CONTACT THIS REVIEWER. |
| | |
| | |
| | DEWEY PALMER |
| | ELECTRICAL PLAN REVIEW II |
| | CONSTRUCTION SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | 561-805-6717 |
| | [email protected] |
| | |