| Plan Review Notes For Permit 08070254 |
| Permit Number |
08070254 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2008-09-18 09:14:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. SEE THE ROOF TILE NOA; THE ONLY FOAM ADHESIVE | | | APPROVED FOR THIS PRODUCT IS POLYPRO. TITE-SET | | | INSULATION ADHESIVE EVALUATION REPORT WAS SUBMITTED; | | | THIS IS AN INSULATION ADHESIVE, NOT A TILE ADHESIVE. | | | THIS IS A COMPONENT IN A ROOF ASSEMBLY, AND IS NOT | | | INCLUDED IN THE ROOF TILE NOA SUBMITTED. PLEASE PROVIDE | | | MORE INFORMATION; SPECIFY AN ASSEMBLY AND PROVIDE | | | PRODUCT APPROVALS WHICH INCLUDE THESE COMPONENTS. | | | | | | IF YOUR INTENTION IS TO INSTALL THE TILE OVER A WOOD | | | DECK WITH ROOF TILE ADHESIVE, PROVIDE THE POLYPRO | | | PRODUCT APPROVAL (AS THIS IS THE ONLY PRODUCT INCLUDED | | | IN THE NOA SUBMITTED). IF YOU WISH TO USE A DIFFERENT | | | ROOF TILE ADHESIVE, ADDITIONAL INFORMATION (INCLUDING | | | ENGINEERING) WILL BE REQUIRED. PLEASE CONTACT ME BY | | | TELEPHONE IF YOU WISH TO USE A TILE FOAM ADHESIVE OTHER | | | THAN THE ONE INCLUDED IN THE NOA (POLYPRO). | | | | | | |
|