| 2009-01-02 10:16:29 | BUILDING PLAN REVIEW |
| | PERMIT: 08070127 |
| | ADD: 550 S ROSEMARY |
| | CONT: ALLIANCE |
| | TEL: (561)818-7777 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION REVIEW DATED DEC. 5/2008 |
| | 8X11 |
| | ACTION: DENIED |
| | 2 HR RATED VESTIBULE ASSEMBLY |
| | |
| | 1) 106.1.2 ADDITIONAL INFORMATION REQUIRED. PLANS FAIL |
| | TO INDICATE THE LOCATION OF THIS VESTIBULE. SPOKE WITH |
| | ARCHITECT JORY SOPOURN III ABOUT THIS REVISION, AND |
| | WHAT WILL BE REQUIRED |
| | FOR THE CITY TO ACCEPT THE DETAIL UNDER SECTION 104.11 |
| | ALTERNATE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION |
| | AND EQUIPMENT, APPROVED BY THE INTERUM BUILDING |
| | OFFICIAL ROBERT BROWN. |
| | |
| | A) PROVIDE ADDITIONAL INFORMATION WHEREAS WHERE EACH OF |
| | THE AREAS ON THE PLAN IS LOCATED, STAIRWELL, ABOVE |
| | CEILING AND OR IMPROV TENANT SPACE. |
| | |
| | B) PROVIDE A FULL HEIGHT DETAIL WITH CEILING OR DECK |
| | ABOVE TO TENANT FLOOR SPACE, INDICATE CEILING LEVEL, |
| | UNDERSTOOD THAT THE DRYWALL OF THE ENCLOSURE DOES NOT |
| | EXTEND TO DECK ABOVE, THAT IS THE REASON FOR THE 2 HR |
| | RATED CEILING WITHIN THE VESSTIBULE, NO FUEL LOADS TO |
| | BE ABOVE THE RATED CEILING! |
| | |
| | C) PROVIDE A FLOOR PLAN INDICATING THE LOCATION OF THE |
| | REVISON FOR CLARIFICATION. |
| | |
| | VESTIBULE IS PART OF A 2HR RATED STAIRWELL ENCLOSURE |
| | AND TO COMPLY WITH 1019.1. ( ALTERNATE MEANS AND |
| | MATERIALS) |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |