| 2008-07-22 13:11:33 | 2004 FBC W/2007 REVISIONS |
| | POOL CABANA |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL |
| | BE REQUIRED. |
| | |
| | 2) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY |
| | CALCULATION FORMS PER FBC CHAPTER 13. |
| | |
| | 4) IN ORDER TO CLAIM THE CEILING FAN CREDIT ON THE |
| | ENERGY CALCULATIONS, THE PLANS ARE REQUIRED TO SHOW THE |
| | REQUIRED CEILING FAN SIZES AND LOCATIONS. SEE FBC |
| | 13-600. |
| | |
| | 5) SPECIFY THE WATER HEATER ON THE ENERGY CALCULATIONS. |
| | SEE FBC 13-600. |
| | |
| | 6) THE STRUCTURAL PLANS ARE REQUIRED TO BE SIGNED, |
| | SEALED AND DATED BY THE ENGINEER AS REQUIRED BYFS 471 |
| | AND FAC 61G15-23.002. |
| | |
| | 7) THE SOIL REPORT IS REQUIRED TO HAVE THE ORIGINAL |
| | SIGNATURE OF THE ENGINEER. SIGNATURE STAMPS AND |
| | PHOTOCOPIED SIGNATURES ARE NOT ACCEPTABLE. SEE FS 471 |
| | AND FAC 61G15-23.002. |
| | |
| | 8) THE TRUSS DRAWINGS ARE REQUIRED TO HAVE THE ORIGINAL |
| | SIGNATURE OF THE TRUSS ENGINEER. A COVER SHEET IN |
| | COMPLIANCE WITH FAC 61G15-23.002 MAY BE USED. SEE FS |
| | 471 AND FAC 61G15-23.002. |
| | |
| | 9) THE TRUSS LAYOUT IS REQUIRED TO BE REVIEWED AND |
| | APPROVED BY THE DESIGNER OF RECORD FOR THE STRUCTURE. |
| | SEE FBC R301.1. PLEASE HAVE THE DESIGNER OF RECORD PUT |
| | HIS SHOP DRAWING REVIEW STAMP OR OTHERWISE INDICATE ON |
| | THE TRUSS LAYOUT THAT THEY HAVE BEEN REVIEWED AND |
| | APPROVED. |
| | |
| | 10) SUBMIT TWO COPIES OF PRODUCT APPROVALS AS REQUIRED |
| | BY DCA RULE 9B-72 FOR THE LINTELS, STRUCTURAL WINDOW |
| | MULLIONS, AND FIXED GLASS WINDOWS (ROUND, ARCH TOP & |
| | RECTANGLE). |
| | |
| | 11) SUBMIT THE INSTALLATION INSTRUCTIONS FOR THE SINGLE |
| | AND DOUBLE OUTSWING GLAZED DOORS AS REQUIRED BY RULE |
| | 9B-72. PLEASE PROVIDE ONE OF EACH DOOR TYPE WITH EACH |
| | SET OF PLANS. BOTH THE SINGLE DOOR PRODUCT APPROVALS |
| | WERE ATTACHED TO A PLAN AND BOTH THE DOUBLE DOOR |
| | APPROVALS WERE ATTACHED TO THE OTHER PLAN. |
| | |
| | 12) SPECIFY WHICH ONE OF THE METHODS LISTED IN THE |
| | ROOFINGPRODUCT APPROVAL WILL BE USED TO ATTACH THE |
| | ROOF TILES. CIRCLE THE ONE THAT WILL BE USED ON THE |
| | NOAS. FBC R905.3.7. |
| | |
| | NOTE: PLEASE DO NOT STAPLE THE PRODUCT APPROVALS AND |
| | OTHER DOCUMENTS TO THE PLANS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |