| 2008-09-04 10:52:08 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | ****FROM PREVIOUS REVIEW: |
| | |
| | 2. INFORMATION MISSING FROM TITLE BLOCK. |
| | SEE FAC 61G1-16.004 PLANS PREPARED BY A |
| | REGISTERED ARCHITECT SHALL INCLUDE A TITLE |
| | BLOCK WHICH MUST INCLUDE |
| | - STATE THE FIRM NAME, ADDRESS & TELEPHONE NUMBER |
| | - STATE THE FIRM LICENSE NUMBER |
| | - STATE PROJECT NAME OR IDENTIFICATION |
| | - STATE DATE PREPARED |
| | - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEAL |
| | - INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE |
| | PLANS |
| | |
| | NOTE: PLANS MISSING PRINTED NAME, PRINTED LICENSE |
| | NUMBER, AND CERTIFICATE OF AUTHORIZATION NUMBER. |
| | ****RESPONSE NOTED, BUT THE CERTIFICATE OF |
| | AUTHORIZATION IS NOT SHOWN IN THE TITLE BLOCK OF THE |
| | ARCHITECT. THIS IS REQUIRED ON ALL SHEETS WITH BAI |
| | ARCHITECTURE INC TITLE BLOCK ON IT. (SEE ATTACHED |
| | SHEET). |
| | |
| | 4. SHEET A201 DETAILS 8 & 9 INTERIOR TOILET ROOM |
| | ELEVATIONS: PLEASE PROVIDE THE FOLLOWING REQUIRED |
| | INFORMATION PER FBC-CHAPTER 11, FLORIDA ACCESSIBILITY |
| | CODE. |
| | |
| | A} WATER CLOSET= CLEARLY INDICATE THE HEIGHT OF THE |
| | WATER CLOSET 17"-19". PER SECTION 11-4.16.3. |
| | B} LAVATORY= CLEARLY PROVIDE A CLEARANCE OF AT LEAST 29 |
| | INCHES ABOVE THE FINNISH FLOOR TO THE BOTTOM OF THE |
| | APRON. KNEE AND TOE CLEARANCE SHALL COMLY WITH FIGURE |
| | 31. PER SECTION 11-4.19.2. |
| | ****RESPONSE NOTED, BUT NO CLEARANCE IS INDICATED FOR |
| | THE LAV. |
| | |
| | 5. SHEET M102 WATER RISER DIAGRAM: PER FBC-PLUMBING |
| | SECTION 604.9 WATER HAMMER. WATER HAMER ARRESTORS SHALL |
| | BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S |
| | SPECIFICATIONS. MANUFACTURE'S SPECIFICATIONS FOR BOTH |
| | MODELS PPP AND SIOUX CHIEF STATE THAT WATER HAMMER |
| | ARRESTORS SHALL BE PLACED AS NEAR TO THE SOURCE OF THE |
| | SHOCK AS POSSIBLE. PLEASE LOCATE WATER HAMMER ARRESTORS |
| | CLOSE TO FIXTURE. |
| | ****RESPONSE NOTED, BUT THE WATER HAMMER ARRESTOR IS |
| | SHOWN LOCATED IN THE CEILING. PLEASE LOCATE THE |
| | ARRESTOR NEXT TO THE FIXTURE. PDI-WH 201. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |