| Date |
Text |
| 2008-07-28 11:31:47 | PLUMBING PLAN REVIEW: |
| | DENIED **2ND TIME: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH |
| | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE |
| | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW |
| | COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW |
| | COMMENTS. |
| | NOTE: THERE WERE NO COMMET RESPONSES FROM THE DESIGNER |
| | AND NONE OF THE PREVIOUS PLUMBING REVIEW COMMENTS WERE |
| | ADDRESSED |
| | |
| | 1. SHEET A3 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT |
| | REFLECT THE FLOOR PLAN OF SHEET A1 AND IS NOT CODE |
| | COMPLIANT PER FBC- PLUMBING THE FOLLOWING SECTIONS. |
| | |
| | A} BATHTUB MISSING FROM RISER DIAGRAM. PER SECTIONS |
| | 401.1 AND 701.1 SCOPE. |
| | |
| | B} BOTH SINKS IN THE KITCHEN REQUIRE VENTS. PER |
| | SECTION 901.2.1 VENTING REQUIRED. |
| | |
| | C} SINK IN THE LAUNDRY REQUIRES A VENT. PER 901.2.1 |
| | VENTING REQUIRED. |
| | |
| | D} THE WASHING MACHINE IS DESIGNED WITH A PROHIBITED |
| | "S" TRAP. PER SECTION 1002.3 PROHIBITED TRAPS (5). THE |
| | WASHING MACHINE REQUIRES A VENT. PER SECTION 901.2.1 |
| | VENTING REQUIRED. |
| | NOTE: PLEASE DESIGN THE WASHING MACHINE PER THE |
| | FOLLOWING. |
| | |
| | SECTION 406.3 WASTE CONNECTIONS.THE TRAP AND FIXTURE |
| | DRAIN FOR AN AUTOMATIC CLOTHES |
| | WASHER SHALL BE A MINIMUM OF 2 INCHES |
| | (51MM) IN DIAMETER. THE AUTOMATIC |
| | CLOTHES WASHER FIXTURE DRAIN SHALL |
| | CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| | STACK A MINIMUM OF 3 INCHES (76MM) IN |
| | DIAMETER. |
| | |
| | SECTION 802.4 STANDPIPES.STANDPIPES SHALL BE |
| | INDIVIDUALLY TRAPPED. STANDPIPES SHALL |
| | EXTEND A MINIMUM OF 18 INCHES (457MM) |
| | AND A MAXIMUM OF 42 INCHES (1066MM) |
| | ABOVE THE TRAP WEIR. ACCESS SHALL BE |
| | PROVIDED TO ALL STANDPIPES AND DRAINS |
| | FOR RODDING. |
| | NOTE: CLEARLY INDICATE THE REQUIRED STANDPIPE FOR THE |
| | WASHING MACHINE. |
| | |
| | SECTION 708.7 MINIMUM SIZE. CLEANOUTS SHALL BE THE |
| | SAME NOMINAL SIZE AS THE PIPE THEY SERVE UP TO 4 INCHES |
| | (102MM) |
| | NOTE: WASHING MACHINE CLEANOUT SHALL BE 3". |
| | |
| | SECTION 708.9 ACCESS. ACCESS SHALL BE |
| | PROVIDED TO ALL CLEANOUTS. |
| | NOTE: WASHING MACHINE CLEANOUT SHALL BE LOCATED AT 4' |
| | A.F.F. |
| | |
| | E} "OK" COMMENT ADDRESSED. |
| | |
| | 2. SHEET A1 NEW FLOOR PLAN INDCATES ICE. IS THIS AN |
| | ICE MAKER? NOTE: THE ICE MAKER MAY REQUIRE A DRAIN PIPE |
| | FROM THE SANITARY SYSTEM. PLEASE SUBMIT TWO COPIES OF |
| | ICE MAKER MANUFACTURE SHEETS AND DESIGN SANITARY SYSTEM |
| | ACCORDINGLY IF A DRAIN IS REQUIRED. PER FBC- PLUMBING |
| | SECTION 701.1 SCOPE. WHERE A TRAP SEAL IS SUBJECT TO |
| | LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE |
| | INSTALLED. PER FBC- PLUMBING SECTION 1002.4 TRAP |
| | SEALS. |
| | |
| | **THE FOLLOWING ARE NEW COMMENTS |
| | |
| | 3. SHEET A1 SCOPE OF WORK INDICATES IN THE GUEST |
| | BEDROOM (NEW MASTER CLOSET) ADD DRAINS AND CAP FOR |
| | SINKS (FUTURE APPLICATION) AND ADD WC WASTE LINE AND |
| | CAP (FUTURE USE). THESE FUTURE FIXTURES AND LAYOUT MUST |
| | BE INDICATED ON THE PROPOSED NEW FLOOR PLAN AND THE |
| | SANITARY WASTE, VENTS, TRAPS AND CLEANOUTS WITH SIZES |
| | MUST BE CLEALY INDICATED ON THE SANITARY RISER DIAGRAM |
| | FOR THESE FUTURE FIXTURES ON SHEET A3. PER (W.P.B. AS |
| | AMENDED) SECTION 106.3.5.4(9) PLUMBING AND FBC-2004 |
| | PLUMBING SECTION 701.1, AND SECTION 901.1 SCOPE. |
| | |
| | 4. SHEET A1 INDICATES GAS APPLIANCES (GAS W.H.& GAS |
| | RANGE): PLEASE KNOW THAT A GAS PERMIT IS REQUIRED FOR |
| | THIS WORK. A LICENSED GAS OR PLUMBING CONTRACTOR SHALL |
| | SUBMIT PLANS WITH PERMIT APPLICATION. ALL GAS |
| | INSPECTIONS ARE TO BE COMPLETE BEFORE THE FINAL |
| | INSPECTION. |
| | |
| | 5. SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR |
| | TIMES THE FEE. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | PHONE= (561) 805-6730 |
| | FAX= (561) 805-6731 |