Plan Review Notes
Plan Review Notes For Permit 08060641
Permit Number 08060641
Review Stop P
Sequence Number 1
Notes
Date Text
2008-07-01 15:40:10PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 DECLARE THE GOVERNING CODE. (FBC-2004
 WITH 2007 REVISIONS). PER (W.P.B. AS AMENDED) SECTION
 106.5 RETENTION OF CONSTRUCTION DOCUMENTS.
  
 2. SHEET A-1 DEMOLITION PLAN: PLEASE ADD THE FOLLOWONG
 TO NOTES, PER FBC-2004 W/07 REV. PLUMBING, SECTION
 704.5 DEAD ENDS: IN THE REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A
 PLUMBING PERMIT IS REQUIRED AND AN INSPECTION IS
 REQUIRED OF THE PLUMBING DEMO WORK PRIOR TO COVERING
 THE DEMO WORK WITH FINNISH WALLS, CIELINGS, OR POURED
 CONCRETE SLABS.
  
 3. SHEET MEP-1 IS IDENTIFIED WRONG AS SHEET MEP-2 PER
 THE SHEET INDEX ON SHEET A-1. PER (W.P.B. AS AMENDED)
 SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. SHEET MEP-1 SANITARY RISER DIAGRAM: THE SHOWER
 REQUIRES A VENT. PER FBC- PLUMBING SECTION 901.2.1
 VENTING REQUIRED.
  
 5. SHEET MEP-1 PLUMBING NOTE #11: AIR CHAMBERS OR
 SHOCK ABSORBERS ARE NOT APPROVED BY THE FBC- PLUMBING
 SECTION 604.9 WATER HAMMER. PLEASE DELETE AIR CHAMBER
 AND SHOCK ABSORBER FROM NOTE #11 AND ADD IN THEIR PLACE
 THE FOLLOWING "WATER-HAMMER ARRESTORS".
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]