| Plan Review Notes For Permit 08060641 |
| Permit Number |
08060641 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-07-04 12:39:42 | | | | | | | DENIED | | | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 & 2007 | | | AMENDMENTS PER 106.1.1 FBC* | | | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 3))PER ACCESSIBILITY REQUIREMENTS OF THE EXISTING | | | BUILDING CODE PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM | | | PER R322.1.1 FBC RES. WITH 29" CLEAR OPENING WHEN DOOR | | | IS OPEN 90 DEGREES | | | | | | 4)PROVIDE CORRECT WIND DESIGN DATA ON DRAWINGS PER | | | 1603.1.4 FBC THE 2006 AMENDMENTS TO THE 2004 FBC | | | REQUIRE BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN | | | THAT IS DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS | | | OPEN GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF | | | 600 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. | | | | | | 5)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | | R313.1.1 FBC RES. | | | | | | 6)SUBMIT A COPY OF THE RECORDED NOTICE OF | | | COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | |
|